Two diagnostic models for PLC controlled flexible manufacturing systems

InternationalJournalofMachineTools&Manufacture39(1999)

1979–1991
TwodiagnosticmodelsforPLCcontrolled exible
manufacturingsystems
W.Hu,A.G.Starr*,A.Y.T.Leung
ManchesterSchoolofEngineering,TheUniversityofManchester,ManchesterM139PL,UK
Received5September1998;accepted18January1999
Abstract
Thecontrolof exiblemanufacturingsystems(FMS’s)isgenerallycharacterisedbylogicalandsequen-tialfunctionsundertheauspicesofaprogrammablelogiccontroller(PLC).Operationalfaultsassociatedwithcontrolprocessesareoftenconfusingtomaintenancepersonnelatworkshoplevel.Thishasresultedinthedevelopmentofautomaticdiagnosistechniques.InthispapertwogenericdiagnosticmodelsbasedonthelogicalfunctionchartandsequentialcontrolprocessofthePLCaredeveloped.Withthetwocomp-lementarymodels,themajoroperationalfaultsofPLCcontrolledFMS’scanbediagnosed.ApplicationofthemodelstoatypicalFMSispresented.©1999ElsevierScienceLtd.Allrightsreserved.Keywords:Discretediagnosis;PLC;FMS;Logicaldiagnosis;Sequentialdiagnosis
1.Introduction
ProgrammableLogicControllers(PLC’s)areusedbymostFlexibleManufacturingSystems(FMS’s)astheirprocesscontrollersbecausetheyareadaptable,modular,user-friendlyandacquiredatlowcost.ForasophisticatedFMS,however,thePLC’scapabilityinfaultdetectionislimitedbecauseofitsin exibleprogrammingsystem[1].ThePLCisalsoarelativelysimpledevice,andhasnoinherentarchitectureforfaultdiagnosisotherthanofitsownfunctionsandhardware.Therefore,itisnecessarytodevelopeffectivemethodsormodelstoassistthemainte-nancepersonnelindiagnostics.
LikethatofanordinaryFMS,thefaultsofaPLCcontrolledFMSusuallyincludestructural*Correspondingauthor.E-mail:a.g.starr@man.ac.uk.
0890-6955/99/$-seefrontmatter©1999ElsevierScienceLtd.Allrightsreserved.
PII:S0890-6955(99)00022-X
Journal of Systems Architecture, 1999, 45(14): 1245-1248. [4] HU W. Two diagnostic models for PLC controlled flexible manufacturing system[J]. ...
two groups: -3- 外文翻译(原文) (1) ...(device models), the symbol table of a PLC ...(flexible manufacturing systems), and ASRSs (...
The diagnostic results were stored to a data base and published to a web...PLC, and human–machine interface (HMI) for a flexible manufacturing system...
Starr, Two diagnostic models for PLC controlled flexible manufacturing systems, International Journal of Machine Tools & Manufature.-1999.39(12)-1979 35. ...