Analusis,1998,26,142-145© EDP Sciences,Wiley-VCH
Headspace GC-SCD monitoring of low volatile sulfur
compounds during fermentation and in wine*
D. Rauhut1,H. Kürbel1,K. MacNamara2and M. Grossmann1
Fachgebiet Mikrobiologie und Biochemie,Forschungsanstalt Geisenheim,
Von-Lade-Straße 1,D-65366 Geisenheim,Germany
2
Irish Distillers Limited,Bow Street Distillery,Smithfield,Dublin 7,Ireland
1
Abstract. A rapid and reliable method for the determination and quantification of volatile sulfur compounds in wine is reported.The analysis was carried out with an automatic headspace injection sampler combined with a cooled injection system and cou-pled with a gas chromatograph and a sulfur chemiluminescence (GC-SCD) detector.The calibration curves were calculated in awine with a very low amount of sulfur compounds. As internal standard ethyl methyl sulfide was used. In dependence on the S-compound the detection limit was in the range of 0.1to3µg/L. A linear response was obtained up to a concentration of about100µg/L with an average correlation coefficient of 0.998. Major advantages are the small sample volume (3 mL),the high repea-tability or reproducibility and a short total analysis time.
Key words. Low volatile sulfur compounds in wine – automatic headspace technique – sulfur chemiluminescence detector.
Introduction
Very low levels of sulfur (S)-compounds give wines theird istinctive aro ma,but in higher concentrations they cancreate unappealing flavours. A rapid and reproducible detec-tion of S-compounds in wine becomes more and morei mportant for quality control and re search analy sis.Therefore a multi-purpose-sampler,designed for liquid largevolume,gaseous and headspace samples was tested for itssuitability in the headspace analysis of low volatile S-com-pounds in wine and during fermentation.
ionization detector (FID). The SCD is a very sensitive andselective detector for sulfur compounds in different kinds ofbeverages. It gives a linear response over a wide concentra-tion range and there is no problem of hydrocarbon quen-ching [1,3,4,6].
The liner of the CIS-3 was filled with a porous polymerto increase the enrichment capacity. Sensitivity of the sys-tem was enhanced by the addition of sodium chloride to thes ample. A concentration of 0.8g NaCl/3mL sample(0.27g/mL) enhanced the response of the sulfur compoundsabout 80 to 100 per cent.
The first studies were carried out with hydrogen as car-rier gas. Afterwards helium (He) was used,because in futurethe GC Sich ro mat 2 will be coupled with a mass spectrometer system.
Ethyl methyl sulfide (EMS) was used as internal standard(30µg/L EMS).Analysis conditions
Headspace Single Injection (HSI)
Injection:total volume 5000µL (5 times 1000µL of eachsample).
Temperature:syringe 60°C and preheating station 60°C.Preheating time:45min.
Cooled injection System CIS-3
Liner:filled with 25mg PorapakQ 80/100mesh (WGA,Düsseldorf,Germany.
Temperature program: 60°C,12°C/sì180°C for 8min.Split flow through the liner:50 mL/min.Experimental
An automatic headspace sampling system (Multi Purp oseSampler used as Headspace-Sampler,G erstel GmbH,Mülheim a.R.,Germany) with a volume,temperature andspeed controlled 1000µL gas tight syringe was combinedwith a temperature controlled cooled injection system (CIS-3,Gerstel GmbH). Regular 5mL GC-vials filled with only3mL sample were used as headspace sampling vials. Thewine samples are stored at 4°C before sample preparation.A high advantage of this method is the low sample volume.Each sample is heated for the same period of time at thesame temperature in the preheating station (45min). Afterp re heating the sample is injected into the cooled CIS-3(Gerstel) for cold trapping,focussing and enrichment andafter heating up to the desired temperature transferred to thecapillary column in either split or splitless mode.The mosts uitable column for the detection of low vo latile S-com-pounds in wine seems to be a SPB-1-Sulfur (Supelco INC.,Bellefonte PA,USA) which was also used in this study.Thesamples we re inve stigated on a Siemens Sich ro mat2( Siemens,K arl sru he,G erm any) fitted with a SCD3 50B(Sievers Instrument,Boulder,Colorado,USA) sulfur chemi-

142
Article available at or
-phase microextraction method of use in monitoring...volatile compounds prior to GC injection – ...
Volatile composition of hybrids Citrus juices by headspace solid-phase microextraction-gas chromatog_理学_高等教育_教育专区。Volatile composition of hybrids ...
Keywords: Epichlorohydrin; Volatile organic compounds...sulfur(IV) to form a product with a terminal ...For monitoring of drinking-water quality (LODECH ...
ltration for control of volatile organic compounds ...C during monitoring. These data suggest a hybrid...ed a range of organic sulfur compounds and ...
Volatile composition of hybrids Citrus juices by headspace solid-phase microextraction-gas chromatog_理学_高等教育_教育专区。Volatile composition of hybrids ...
热门文档