太阳能电池板安装手册

INSTALLATION MANUAL FOR CRYSTALLINE SOLAR PHOTOVOLTAIC MODULES Rev.G
system, please always take into consideration the variation of the voltage under different temperatures (please check the respective temp. coefficients of the modules, the Voc of the modules will be rise when the temperature drops);
For example: with TSM-190DC01 modules (Max. System voltage is 1000V) the maximum series modules configuration number should NEVER can exceed N= 17 (1000V/56.22V = 17.8), taking into consideration the possible variation of the voltage due to the lowest temperature in winter at specified location can reach -40℃.
When SPV modules connect in series, the voltage output of the whole string will be equal to the sum of all modules; when the SPV modules connect in parallel, the output current will be equal to the sum of each branch current. We suggest that every series SPV module string should be fused prior to be connected with other strings. Please refer to the applicable regional and local codes for additional fuse requirements. When necessary, please install blocking diodes to protect SPV module or SPV system been damaged by reverse current.
The module frame is made of anodized aluminum, and therefore corrosion can occur if the module is subject to a salt water environment with contact to a rack of another type of metal (Electrolysis Corrosion). If required, PVC or stainless steel washers can be placed between the SPV module frame and support structure to prevent this type of corrosion. Module support structures that are to be used to support SPV modules at correct tilt angles should be rated for wind and snow loads and comply with local and civil codes prior to installation.
Trina Solar SPV modules can be mounted using the following methods:
(Note: All installation methods herein are only for reference, and Trina solar will not provide related BOS components, the system installer or trained professional personnel must be responsible for the PV system’s design, installation, and mechanical load calculation and security of the system.)
Using corrosion-proof screws (M8) in the existing installing holes in the module frame.
Using suitable module clamps on the long side of the module frame to mount the modules (“portrait orientation”) Using suitable module clamps on the short side of the module frame to mount the modules (“landscape orientation”)
1) Screw fitting: The frame of each module has 4 mounting holes (Length* Width: 12mm*9mm) used to secure the
modules to supporting structure. The module frame must be attached to a mounting rail using M8 corrosion-proof screws together with spring washers and flat washers in four symmetrical locations on the SPV module. The applied torque should be approximately 8 Newton-meters. Please find detailed mounting information in the below illustration:
Mounting rail
M8 screw
4-φ9*12 installation hole
Washer
Mounting rail
Nut
Cross section A-A enlarged
Figure3. SPV module installed with Screw fitting method*
Address: No.2 Trina Road, Trina PV Park, New District, Changzhou, Jiangsu, P.R. China
KX-TDA安装手册_manual_信息与通信_工程科技_专业资料。KX-TDA30/KX-TDA100...章节 6 安装 (Installation)— KX-TDA30 介绍安装 KX-TDA30 的工序。提供...
图 10 Main Rack 11 图 11 选择 IC200UDR040/140/440 图 12 Module Catalog...追日程序流程 15 表1 名称 E_Stop start Manual_Auto MorningSun_Contr ...
TM---Manual--TMG安装与配置手册_IT/计算机_专业资料。MS TMG安装与配置手册ForeFront TMG Manual Book Shanghai Redmaple ForeFront TMG Manual Book 1 前期准备...
atv61安装手册s_installation_manual_cn_v2_信息与通信_工程科技_专业资料。Altivar 61 异步电机变频器 0.37 (0.5 HP) ... 45 kW (60 HP)/200 - 240...
RVT Manual CN---中文版rvt新型安装手册_电子/电路_工程科技_专业资料。ABB 新版彩屏RVT样本RVT 功率因数控制器 RVT 安装和操作说明 目录前言 ......
10G OEO 使用手册manual-1_信息与通信_工程科技_专业资料。10G OEO 传输子...4 2. INSTALLATION AND CONNECTION 安装与连接 ... 4 ...
FSP180-60SPV中文资料_电子/电路_工程科技_专业资料。元器件交易网www.cecb2b... Manual selection Frequency: 47~63Hz Input Current: 7A (RMS) @115V AC,...
MTA-ADW-1 开关量控制使用手册Manual_V2.0_2010.10_电子/电路_工程科技_...安装尺寸图 6.MTA-ADW-1油门执行器 开关量控制使用手册 www.hesmor.de 目录...
Installation/SystemRequirements --- 3 怎样获得 怎样获得Ubuntu安装光盘 安装光盘...module=via_rhine multicast=yes port=MII speed=10MB/s *-network DISABLED ...
KNT-SPV01 光伏发电实训系统 使用说明书(2011 年...Module Catalog 对话框 (5)在如图 13 所示的 ...追日程序流程 15 表1 名称 E_Stop start Manual_...
热门文档