3058IEEETRANSACTIONSONINSTRUMENTATIONANDMEASUREMENT,VOL.61,NO.11,NOVEMBER2012
ErrorAnalysisandGyro-BiasCalibrationofAnalytic
CoarseAlignmentforAirbornePOS
JianliLi,JianchengFang,Member,IEEE,andMinDu
Abstract—ThePositionandOrientationSystemisintegratedmeasurementequipmentforairborneremotesensingsystem.Thecalibrationofgyrobiasesisaneffectivewaytoreduceazimuthmisalignmentandnavigationerrorofstrapdowninertialnaviga-tionsystem(SINS).Accordingtotheanalytic-coarse-alignmentprinciple,thesensitivitiesofEulerangleswithrespecttoinertialsensorbiasesareanalyzeduniquely.TheerrorsofEarthrotationrateinbodyframecausedbyinitialmisalignmentareobtained.Basedonthetransformationmodelofgyrobiases,anovelan-alyticcalibrationofgyrobiaseswitharbitrarydoublepositionisproposed.Thesimulationandexperimentresultsshowthatthemethodcanaccuratelycalibratethegyrobiases,improvetheprecisionofinitialalignmentandinertialnavigationforSINS,andverifytheef ciencyoftheproposedmethod.
IndexTerms—Calibration,gyrobias,inertialnavigationsystem,initialalignment,PositionandOrientationSystem(POS).
I.INTRODUCTION
HEPOSITIONandOrientationSystem(POS)isdedi-catedstrapdowninertialnavigationsystem(SINS)/GlobalPositioningSystem(GPS)integratedmeasurementequipmentforairborneremotesensingsystem[1].Itcansuccessivelypro-videposition,velocity,andattitudeoftheairbornesensorandhasbecomeoneofthekeytechnologiesforairbornedirectgeo-referencing[2].TheperformanceoftheairbornePOSchie ydependsonahigh-precisionSINS[3],[4].TheSINSsolvesNewton’sequationsofmotionbyintegratingaccelerationsandangularratessensedbyinertialsensors[5].ThenavigationerrorsofSINSdivergeslowlywithtimeduetotheexistenceofthebiasesofinertialsensorsandinitialmisalignments[6].ThecalibrationofgyrobiasesisaneffectivewaytoreduceazimuthmisalignmentandnavigationerrorofSINS[7].
Generally,theinitialalignmentprocessisdividedintotwophases,i.e.,coarseand nealignments.Thepurposeofcoarsealignmentistoprovideafairlygoodinitialconditionforthe
ManuscriptreceivedJanuary12,2012;revisedMay3,2012;acceptedMay4,2012.DateofpublicationSeptember6,2012;dateofcurrentversionOctober10,2012.ThisworkwassupportedinpartbytheNationalNaturalScienceFoundationofChinaunderGrants60904093,60825305,61121003,60905056,61004140,and61104198andinpartbytheNationalProgramonKeyBasicResearchProjectsofChinaunderGrant2009CB724002.TheAssociateEditorcoordinatingthereviewprocesswasDr.GeorgeXiao.
J.L.LiandJ.C.FangarewiththeScienceandTechnologyonIn-ertialLaboratoryandtheKeyLaboratoryofFundamentalScienceforNa-tionalDefense—NovelInertialInstrumentandNavigationSystemTechnology,SchoolofInstrumentationScienceandOptoelectronicsEngineering,BeijingUniversityofAeronauticsandAstronautics,Beijing100191,China(e-mail:lijianli@buaa.edu.cn).
M.DuiswiththeInstituteofDisasterPrevention,Sanhe065201,China(e-mail:dumin@fzxy.edu.cn).
Colorversionsofoneormoreofthe guresinthispaperareavailableonlineatdoc.guandang.net.
DigitalObjectIdenti er10.1109/TIM.2012.2202186
T
ne-alignmentprocessing[8],[9].SincetheconventionalerrormodelofSINSisnotcompletelyobservableinastationarybaseandtheobservabilitydegreeofsomestatesisweak,thus,itisineffectivetoestimatethestatesbyaKalman lteratthistime.Theobservabilitydegreeofstatesevengreatlyin uencesthespeedandaccuracyofinitialalignmentandcalibration[10],[11].Inthiscase,canthegyrobiasesbecalibratedaccurately,andcaninitialmisalignmentbereducedinanalytic-coarse-alignmentphases?Theaforementionedinterestingideastim-ulatesustostudytheerrorcharacteristicsoftheanalyticcoarsealignmentandthecalibrationmethodsofgyrobiasesforSINS.Theobservabilitydegreeofstatescanbeimprovedbychang-ingthebodyattitude.Wecallthatmultipositionalignmenttechniqueasopposedtoa xed-positionalignmentthatiscon-ventionallypracticed.Thegyrobiasescanbecalibratedthroughmultipositionanalyticalignmentmethod[12].Prielpresentsa90 double-positionalignmentmethod,throughwhichthegyrobiasescanbecalibratedandtheaccuracyofinitialalign-mentcanbeimproved[13].Chengetal.proposedamethodofaccurategyro-biasmeasurementforSINS[14].Byusingagyrocompassloop,two-horizontal-axisgyrobiasescanbemeasuredandcompensated[15].Chungetal.proposeda180 double-positionalignment,whichrotatesSINSwithrespecttoheadingaxisbyarotatabledevice[16].Thosemethodscanachieveahighaccuracyinshorttime.However,aspecialrotatabledeviceisprerequisitetorotateSINSforalldouble-positionalignmentmethodsintroducedbefore,whichisveryinconvenientformanyapplications[17],[18].
Tosolvethoseproblems,accordingtothecoarse-alignmentprinciple,thesensitivityofEulerangleswithrespecttoin-ertialsensorbiasesisanalyzeduniquely.TheerrorsofEarthrotationrateinbodyframecausedbyinitialmisalignmentareobtained.Basedonthetransformationmodelofgyrobiases,anovelanalyticalgorithmofgyro-biascalibrationwitharbitrarydoublepositionisproposed.ThesimulationandexperimentresultsshowthatthemethodcanaccuratelycalibratethegyrobiasesandachieveaccurateinitialattitudeofSINSinshorttimewithoutotheraccessoryinstrument.ThemeasurementprecisionofSINSisimprovedandveri estherationalityandef ciencyoftheproposedmethod.
II.CALIBRATIONMETHODOFGYROBIASES
A.PrincipleofConventionalAnalyticCoarseAlignmentItiswellknownthattheself-alignmentrequirementistobethemeasurementoftwononcollinearvectors,thelocalgravityg,andtheEarthrateωie,inbothbodyframes,
0018-9456/$31.00©2012IEEE