1. Introduction
When placing parts adjacent to premounted parts (parts that are not completely secured on the paneldue to the pins not having been inserted properly), the parts that are to be placed may interfere with thepremounted parts when the Z-axis is being lowered to the placement position, which can causedamage to parts.
To prevent this problem from occurring, the adjoining placement function is now supported. Whenusing this function, the Z-axis is lowered slightly (to the adjoining placement preparation height) at aposition which is offset from the placement position (the adjoining placement preparation position),before the head moves to the placement position.
This manual describes how to use the adjoining placement function to place parts.
2. Required items
The following items are required in order to use the adjoining placement function.
M6/M6S module
H01 head or OF head
NXT Application V4.20 and later
Fuji Flexa V3.3.0 and the adjoining placement function support patch Data checker 0043

(IPS) 6 nozzle operation Placement height optimization based on actual part ...When not using the IPS function, set [Part Sensor] to [No]. Fuji ...
(IPS) 6 nozzle operation Placement height optimization based on actual part ...When not using the IPS function, set [Part Sensor] to [No]. Fuji ...