5GT cannot be upgraded because flash shows no space available [KB9849] Show KB Properties
PROBLEM OR GOAL:
5GT can not be upgraded from ScreenOS 5.3r3 to 5.3r6. The following error message is seen when trying to upgrade ScreenOS
via WebUI:
"firmware update failed"
via TFTP/CLI:
“Cannot write system image file flash:$NSBOOT$.BIN"
SOLUTION:
Run the following command to verify whether there is enough free space available in file system. In this example, there are 0 bytes free. 5GT-> get file info
There are 0 bytes free (31262720 total) on disk "flash:"
Run the following command to fix the file system:
5GT->exec vfs check flash:fix
After resetting the firewall, ScreenOS upgrades will be successful.