凝汽器循环水系统节能节水优化改造
谭旭东,王中伟
华能威海发电有限责任公司,山东威海 264205
[摘 要] 华能威海发电有限责任公司125MW1号机组循环水系统存在循环水泵出力设计裕量
偏大、效率偏低、凝汽器水室聚集空气、循环水泵淡水润滑消耗水量较大浪费水资源等问题,影响了机组运行经济性。通过对循环水系统进行优化技术改造后,机组夏季可无煤增功率约500kW,循环水泵冬季节约厂用电量约22.5万kW#h,年节约淡水约10万t,综合效益约120万元/年。
[关 键 词] 125MW机组;凝汽器;循环水泵;变频调速;节能节水[中图分类号] TK264.1[文献标识码] B
[文章编号] 1002-3364(2009)07-0069-03
[DOI编号] 10.3969/j.issn.1002-3364.2009.07.069
RETROFITFOROPTIMIZINGTHECONSERVATIONOFENERGY
ANDWATERINCIRCULATINGWATERSYSTEM
TANXu-dong,WANGZhong-wei
HuanengWeihaiPowerPlant,Weihai264205,ShandongProvince,PRC
Abstract:Theproblemsexistingincirculatingwatersystemofcondenserforunitno.1inHuanengWeihaiPowerPlant,suchasthelargeallowanceofoutputcapacityforthecirculatingwaterpump,lowerefficiencyofthesaidpump,theairaccumulationinwaterchamberofthecondenser,aswellas
greaterconsumptionoffreshwaterusedforlubricatingthewaterpump,etc.,affecteconomicefficiencyoftheunitinoperation.Afteroptimizedtechnicalretrofitcarriedoutforthecirculatingwatersystem,theunitcanadditionallygenerateelectricpowerabout500kWinsummer,cansaveservicepowerforcirculatingwaterpumpabout150kWinwinter,thedailyaverage-watersavingbeing400t.Keywords:125MWunit;condenser;circulatingwaterpump;frequencyconvertingspeedregulation;en-ergyandwater-saving
华能威海发电有限责任公司(华能威海发电厂)中,1号机组循环水泵(循泵)和循环水系统存在较多125MW1号机组循环水系统配套2台立式循环水问题,影响了机组运行经济性,为此,对1号机组循环泵,凝汽器采用直流供水冷却,冷却介质为海水。运行
水系统进行了优化改造。
作者简介: 谭旭东(1965-),男,华能威海发电厂安全生产部汽轮机专工。E-mail:TXD_58@163.com
69
华能威海发电厂 谭旭东 300MW纯凝机组供热改造介绍 ...1.1响应国家“节能减排”号召; ? 以大代小 量 ...3.4 改造后对补水系统的要求 ? 量小时进入凝汽器...
(1):71—73. 〔4〕 谭旭东 ,王 中伟. 凝汽 器循 环水 系统 节能 节水优 化 改造 〔J〕. 热力发电 ,2009,38(6):69—71. 〔5〕 曾德 良, 王...
(1):71—73. 〔4〕 谭旭东 ,王 中伟. 凝汽 器循 环水 系统 节能 节水优 化 改造 〔J〕. 热力发电 ,2009,38(6):69—71. 〔5〕 曾德 良, 王...