JESD

JEDEC Standard No. 22-A100-B

Page 1

TEST METHOD A100-B

CYCLED TEMPERATURE-HUMIDITY-BIAS LIFE TEST

(From JEDEC Board Ballot JCB-99-80, formulated under the cognizance of JC-14.1 Committee onReliability Test Methods for Packaged Devices.)1 Purpose

The Cycled Temperature-humidity-bias Life Test is performed for the purpose of evaluating the reliabilityof nonhermetic packaged solid state devices in humid environments. It employs conditions of temperaturecycling, humidity, and bias that accelerate the penetration of moisture through the external protectivematerial (encapsulant or seal) or along the interface between the external protective material and themetallic conductors that pass through it.2 Scope

The Cycled Temperature-Humidity-Bias Life Test is typically performed on cavity packages (e.g.MQUADs, lidded ceramic pin grid arrays, etc.) as an alternative to JESD22-A101 or JESD22-A110.3 Apparatus

The test requires a temperature-humidity test chamber capable of maintaining a specified temperature andrelative humidity profile continuously, while providing electrical connections to the devices under test ina specified biasing configuration.

3.1 Temperature and relative humidity

The chamber must be capable of providing controlled conditions of temperature and relative humidity asdescribed in clause 4, Test Conditions.

3.2 Recording device

A recording device (e.g. a chart recorder or a computer) with an interface to suitable chamber monitoringinstrumentation shall be provided for continuous recording of chamber temperature and relative humidity.

3.3 Devices under stress

Devices under stress must be physically located to minimize temperature gradients.

3.4 Minimize release of contamination

Care must be exercised in the choice of board and socket materials, to minimize release of contamination,and to minimize degradation due to corrosion and other mechanisms.

Test Method A100-B

(Revision of A-100-A)

上一页第5页

你可能喜欢

热门文档

相关文档

  • JESD22-A100D-Cycled Temperature-Humidity-Bias Life ...

    JEDEC STANDARD Cycled Temperature-Humidity-Bias Life Test JESD22-A100D (Revision of JESD22-A100-C,October 2007) JULY 2013 JEDEC SOLID STATE TECHNOLOGY ...

  • JEDEC标准族

    JEDEC 工业标准 环境应力试验 [JDa1] JESD22-A100-B Cycled Temperature-Humidity-Bias Life Test 上电温湿度循环寿命试验, (Revision of JESD22-A100-A) ...

  • JESD22-A118

    Samples are subjected to a non-condensing, humid atmosphere, similar to the JESD-22-A101, "Steady State Temperature, Humidity and Bias Life Test", but...

  • JEDEC工业标准

    JEDEC 工业标准 环境应力试验 [JDa1] JESD22-A100-B Cycled Temperature-Humidity-Bias Life Test 上电温湿度循环寿命试验, (Revi...

  • JEDEC 100系列标准

    JEDEC STANDARD Cycled Temperature-Humidity-Bias Life Test JESD22-A100C (Revision of JESD22-A100-B, April 2000) OCTOBER 2007 JEDEC SOLID STATE TECHNOLOGY ...

  • IC可靠性测试项目及参考标准

    (High/ Low Temperature Operating Life)目的: 评估...JESD22-A113-D EIAJED- 4701-B101 评估结果:八...(Temperature Humidity Bias Test)目的: 评估 IC ...

  • SRF-1016Z中文资料

    humidity (autoclave), extreme hot and cold ...life testing as a DC biased elevated temperature ...JESD22-A110B -40°C to +85°C Cycled bias (...

  • SRF-2016Z中文资料

    humidity (autoclave), extreme hot and cold ...life testing as a DC biased elevated temperature ...JESD22-A110B -40°C to +85°C Cycled bias (...

  • SRQ-2116Z中文资料

    humidity (autoclave), extreme hot and cold ...life testing as a DC biased elevated temperature ...JESD22-A110B -40°C to +85°C Cycled bias (...

  • PCMC135T-1R0MF中文资料

    B Bias Current Source Test Condition Temperature :...a period (2) Vibration time : period cycled ...Humidity resistance Inductance change : Within ± ...

站点地图 | 文档上传 | 侵权投诉 | 手机版
本站所有资源均来自互联网,本站只负责收集和整理,均不承担任何法律责任,如有侵权等其它行为请联系我们.
文档下载 Copyright 2013 doc.guandang.net All Rights Reserved.  -  email