1564IEEETRANSACTIONSONINDUSTRIALELECTRONICS,VOL.53,NO.5,OCTOBER2006
ANewMethodofIntegrationControlWithInstantaneousCurrentMonitoringforClassDSeries-ResonantConverter
JerzyTadeuszMatysik
Abstract—Inthispaper,theapplicationoftheintegrationcon-trolmethodforclassDtransistorvoltagesourceseries-resonantconvertersusedasdc/dcanddc/acconvertersispresented.First,theintegrationcontrolofthesignalasacombinationoftheres-onantfrequencyanditssubharmonics(subharmonicintegrationcontrol)isdiscussed.Second,themodulationdensityofthepulsesshortingthebridgediagonalforonecurrenthalfwave(semiwaveintegralpulsedensitymodulation)isexplained.Adetailedcontrolcircuitoperation,referredtoasthefourbasicalgorithmsoftheresonantcurrentcontrol,isgiven.Themethodforthecalculationofthevalueandsequenceofthecurrentincrementsforadc/dcconverterispresented.Theresultsofcomputersimulationsandlaboratoryexperimentsdemonstratethattheproposedmethodsallowcontrollingtheconverteroutputquantitiesful llingsoftswitchingconditions(zero-currentswitching)andprovidehigheref ciencyincomparisontootherknownmethods.
IndexTerms—ClassD,integrationcontrol,resonantconverters,zero-currentswitching(ZCS).
principleofthecircuitoperationisbasedontheutilizationoftheelectricalenergystoredinpassiveelementsoftheresonantcircuit.Thatenergycirculationbetweenvoltagesourceandresonantcircuitiscontrolled.Theresonantcircuitadditionallyplaysthepartoftheenergybufferduetothefactthatcurrentiscontinuousevenwhentheswitchesareturnedoff.
Thecurrentmagnitudeinaresonantcircuitissubjecttoconstantchangesthatresultinoutputripplesofsubharmonicfrequencies.Thiscannotbeavoidedwiththiskindofcontrol,butonemaytrytoconstrainitsconsequences.
Theintegrationcontrolmethodsusedsofararebasedonsimplyperiodicallyinsertingade nednumberofdampedpulsesintheresonantcircuit[3]–[5].Inthecontrolmethodsusedin[4],theoutputvoltagecontrolinahalfbridgetopologydc/acconverterisbasedonastepchangeofparameterWthatisthemeasureofresonantcircuitcurrentdamping,i.e.,
W=
kdkr
(1)
I.INTRODUCTION
ERIES-RESONANTcircuit(SRC)converters(Fig.1)be-longtothewidelyusedClassDconverters[1],[2].Theyareappliedatawiderangeoffrequencies(fromseveraltohundredsofkilohertz)andoutputpower.Foruncontrolledoper-ation,theyareoneofthebestsolutionsamongpowerelectronicconvertersbecauseofhighpowerdensity,lowelectromagneticdistortionlevel,andhighef ciency.However,incaseswhenregulationoftheoutputquantities(current,voltage,andpower)isneeded,thecurrentlyusedmethodsdonotguaranteesuchgoodparameters.Theonlymethodthatusesthesamebasicconvertertopologies,butallowsobtainingbothoutputregula-tionandparameterlevelsclosetouncontrolledsystems,istheintegrationcontrolmethod.
Intheintegrationcontrolapproach,changesinthestateoftheswitchesmayonlyoccuratzero(closetozero)current,whiletheoutputquantities(current,voltage,andpower)areaveraged.Thesubharmonicchangedoesnotprovidecontinuouscontroloftheoutputquantities.Theoutputvoltage(current)changesitsvaluestepwise.Inordertoprovidecontinuousoutputcontrol,acontinuouschangeofthecontrolsignalisneeded,andalow-pass lterisusedtoaveragetheoutputquantities.The
ManuscriptreceivedJanuary19,2005;revisedJuly15,2005.AbstractpublishedontheInternetJuly14,2006.
TheauthoriswiththeInstituteofControlandIndustrialElectronics,WarsawUniversityofTechnology,00-661Warsaw,Poland(e-mail:jmatysik@isep.pw.edu.pl).
DigitalObjectIdenti er10.1109/TIE.2006.882007
S
wherekristhenumberofpulses(currenthalfwaves)whentheconverteroperateswiththecurrentincreasing,andkdisthenumberofpulseswhentheconverteroperateswiththecurrentdamping.
Similarcontrolsystemswereusedin[3]and[5]forafull-bridgetopology,wherediscrete(tensteps)regulationofkrandkdhasbeenapplied(kd+kr=10).However,theoutputvoltageundersuchtypeofcontrolhaslimitedrangeandstep-wiseadjustment.Moreover,thedependencybetweentheoutputvoltage(power)andtheinputcontrolsignal(numberofk)ishighlynonlinear.
Onthecontrary,thecontrolmethodsproposedinthispaperallowquasi-continuousandlinearadjustmentsoftheoutputquantities(currentandvoltage)infullrange.Additionally,theyhavethefollowingfeatures:minimizationoftheoutputripples,goodoperationundertransientstates,andshortcircuitsprotec-tion.Thisisachievedbyadditionalinternalcurrentmonitoringandappropriatecontrolalgorithm.Themaingoalofthispaperisthepresentationanddetaileddiscussionofthesenewintegralcontrolmethods.
II.SWITCHINGININTEGRATIONCONTROL
TransistorsinclassDconvertersarecontrolledwithbinarysignals:g1,g2,g3,andg4(Fig.2).However,onlyonetransistormaybeONineachofthetwoconverterlegs.Thestateofthe
0278-0046/$20.00©2006IEEE
with the control mode change by utilizing both current and voltage ...Also, the proposed method is able to guarantee accurate instantaneous values ...
Design of mini-multi-gas monitoring system based ... this new IR detection system with integration, ...control of the instantaneous value of the current...
CONTROL TECHNIQUES FO... 9页 免费喜欢此文档的...It seemed a misinterpretation between instantaneous ...current as follows Closure to Discussion of “A ...
Writing control software in the Ada programming ... monitoring serial ports or LAN, controlling a ... assuming that task execution is instantaneous. ...
method, combined with Runge-Kuta method, is ...The integration over the region of the airgap ...turns and the instantaneous value of the current....
method, combined with Runge-Kuta method, is ...The integration over the region of the airgap ...turns and the instantaneous value of the current....
热门文档