MAX3420 -usb资料
USB Peripheral Controllerwith SPI InterfaceMAX3420E
The first five registers (R0–R4) access endpoint FIFOs.To access a FIFO, an initial command byte sets theregister address and then consecutive reads or writeskeep the same register address to access subsequentFIFO bytes.
The remaining registers (R5–R20) control the operationof the MAX3420E. Once a register address above R4 isset in the command byte, successive byte reads orwrites in the same SPI access cycle (SSlow) incrementthe register address after every byte read or written. This
incrementing operation continues until R20 is accessed.Subsequent byte reads or writes continue to accessR20. Note that this autoincrementing action stops withthe next SPI cycle, which establishes a new registeraddress. Addressing beyond R20 is ignored.
The MAX3420E register map is depicted in Table 1. Fora complete description of all register contents, pleaserefer to the MAX3420E Programming Guide.
R = read, RC = read or clear, RSC = read, set, or clear. Writing to an R register (read only) has no effect. Writing a 1 to an RC bit (read or clear) clears the bit. Writing a zero to an RC bit has no effect.
6_______________________________________________________________________________________

Connect load capacitors (20pF max) to ground on both XI and XO. XI can also be driven with an external 12MHz ±0.25% clock. If driving XI with...
Connect load capacitors (20pF max) to ground on both XI and XO. XI can also be driven with an external 12MHz ±0.25% clock. If driving XI with...