Optimal Design Methodology for LLC Resonant Converter

Optimal Design Methodology for  LLC Resonant Converter

Optimal Design Methodology for  LLC Resonant Converter

Optimal Design Methodology for  LLC Resonant Converter

Optimal Design Methodology for  LLC Resonant Converter

Optimal Design Methodology for

LLC Resonant Converter

Bing Lu, Wenduo Liu, Yan Liang, Fred C. Lee, Jacobus D. van Wyk

Center for Power Electronics Systems

Virginia Polytechnic Institute and State University

674 Whittemore Hall Blacksburg, VA 24061 USA

Abstract: Although LLC resonant converter can achieve wide operation range with high efficiency, lack of design methodology makes it difficult to be implemented. In this paper, based on the theoretical analysis on the operation principles during normal condition and holdup time, the relationship between converter efficiency and operation range with different circuit parameters has be revealed. An optimal design methodology has been developed based on the revealed relationship. A 1MHz, 1kW LLC converter is designed to verify the proposed method.

I. INTRODUCTION

With the development of power conversion technology, power density becomes the major challenge for front-end AC/DC converters [1] [2] [3]. Although increasing switching frequency can dramatically reduce the passive component size, its effectiveness is limited by the converter efficiency and thermal management design. Meanwhile, to meet the holdup time requirement, bulky capacitors have to be used to provide the energy during holdup time, which is only affected by DC/DC stage operation input voltage range [1]. The relationship between holdup time capacitor requirement and minimum DC/DC stage input voltage for different front-end converter power levels is shown in Figure 1. Apparently, wide operation range DC/DC stage can reduce the holdup time capacitor requirement and improve the system power density. However, when the minimum voltage is less than 200V, very limited effects can be observed.

1000800

600

(uF)

Holdup time cap requirement 400

200

DC/DC minimum operation voltage (V) Figure 1. Holdup time capacitor requirement for DC/DC stage with

different minimum input voltage.

To reduce the holdup time capacitor requirement,

different research efforts have been implemented, by using

extra holdup time extension circuit or by developing better

topologies [4][5][6]. Among different solutions, LLC resonant

converter becomes the most attractive topology due to its high

efficiency and wide operation range.

L

Figure 2. LLC Resonant Converter.

nVo/(Vin/2)

0.2

0.4

0.6

0.81

1.2

1.4

f/f0

Figure 3. Gain Characteristic of LLC Converter.

The LLC resonant converter topology is shown in Figure 2. By utilizing the transformer magnetizing inductance, LLC converter modifies the gain characteristic of series resonant converter (SRC). Its voltage gain characteristics for different loads are shown in Figure 3, due to the half bridge structure,

the output voltage is normalized with half of the input voltage. Comparing with SRC, the converter can achieve both Buck mode and Boost mode. When the switching frequency is higher than resonant frequency, voltage gain of LLC converter is always less than one, and it operates as an SRC converter

and zero voltage switching (ZVS) can be achieved. When the switching frequency is lower than resonant frequency, for

different load conditions, both ZVS and zero current switching

(ZCS) could be achieved. At the boundary of ZVS and ZCS

regions, as shown in the dashed line in Figure 3, converter

voltage gain reaches it maximum value.