Comparison of UWB SAR and MIMO-based short-range imaging radars

选填,简要介绍文档的主要内容,方便文档被更多人浏览和下载。

Proceedings of the 6th European Radar Conference

Comparison of UWB SAR and MIMO-based short-range imaging radars

T.G. Savelyev#1, X. Zhuge#2, A.G. Yarovoy#3, L.P. Ligthart#4, B. Levitas*

#1-4

International Research Centre for Telecommunications and Radar, Delft University of Technology

Mekelweg 4, 2628CD Delft, The Netherlands

1

T.G.Savelyev@tudelft.nl

Geozondas Ltd.

LT-03111 Vilnius, Lithuania

2

*

info@geozondas.com

Abstract— This paper compares and analyzes the imaging capability of two ultra-wideband radar systems which are based on synthetic aperture and sparse planar array respectively. The systems comprise the same 3.1-10.6 GHz antennas and video-impulse electronics. The SAR uses a transmit-receive antenna pair installed on 2-D mechanical scanner, while the array represents an multiple input multiple output (MIMO) structure with four transmit and sixteen receive antennas. In both systems digital beamforming is applied to the acquired data. The comparison bases on measurements conducted for the same scenarios.

The paper is organised as follows. Section II describes the hardware of the two systems, Section III introduces a data processing and imaging technique, Section IV presents radar images and compares the performance of SAR and MIMO. Conclusions are summarised in Section V. II. SAR AND MIMO-BASED SYSTEMS

The SAR and MIMO-based systems under comparison use the same antennas and electronics, which were developed by Geozondas Ltd. The antennas are bow ties with reflecting plate. Their bandwidth equals to 3.1 – 10.6 GHz, the gain is 10 dBi @ 6.5 GHz, and the beamwidth is of about 85° in E and H planes at -10 dB level. The electronics, built on video impulse technology, generates a mono-pulse with 30 ps rise time and 41 dBm peak power, and it includes a sequentially sampling receiver that works in the DC-26 GHz band. The pulse repetition frequency is 1 MHz while the operational time window can have a length up to 100 ns, i.e. the unambiguous range is up to 15 m.

The SAR system comprises a Tx-Rx vertically polarized antenna pair with 10 cm separation, mounted on 2-D mechanical scanner, radar electronics and controlling / data acquisition computer. The mechanical scanner moves the antennas automatically according to a given program. In the conducted measurements, the antennas were being moved within the regular 1 x 1 m grid with a step of 1 cm that makes 10 000 data acquisitions per one SAR measurement. The time duration of the measurement was about 4 hours.

The MIMO array represents a specific topology, shown in Fig. 1, which has been optimized by electromagnetic simulation with respect to minimal focused beamwidth and sidelobe level. It includes four Tx and sixteen Rx antennas with vertical polarization. During the measurement, the Tx antennas are working sequentially, and for each transmission the reception is done with an 8-channel receiver in two steps via switch. One array measurement takes about ten seconds. In both SAR and MIMO measurements 256 averages were used to improve the signal to noise ratio.

I. INTRODUCTION

Ultra-wideband (UWB) radar technology is being rapidly developed towards 3-D imaging radar that possesses high down- and cross-range resolution. While the former comes from an UWB spectrum, the latter can be achieved by using either the synthetic aperture radar (SAR) or an antenna array, or their combination.

The SAR approach employs 2-D mechanical scanning usually with one transmit (Tx) and one receive (Rx) antennas. The scattered electromagnetic field is being spatially sampled in a dense regular grid, which makes data acquisition too long. UWB SAR has been widely used in landmine detection by ground penetrating radar (GPR) [1].

The use of antenna array significantly speeds up the data acquisition even in cases when the array consists of independent Tx-Rx pairs working sequentially. Such arrays have been developed for landmine detection and medical imaging [2]. A more advanced GPR system combines SAR in on-track direction with a cross-track linear array that receives the scattered field simultaneously with all antennas [3].

A planar or conformal UWB array with the simultaneous signal reception would be the best solution in many applications. However its design encounters a serious contradiction between the antenna size, spacing in the array and the level of sidelobes of the focused array, especially when high frequencies are used to achieve a high resolution. A sparse array with multiple Tx and multiple Rx antennas (MIMO) can be the optimal solution regarding the above factors plus complexity of the electronics. IRCTR investigated this direction for an application of concealed weapon detection and compared the quality of radar imaging by SAR and MIMO-based systems in the 3.1-10.6 GHz band.