EXTRACTING HEART RATE AND RESPIRATION
RATE USING A CELL PHONE CAMERA
Luis Felipe Jimenez
Department of Computer Science
Kean University Union, NJ 07083 jimluis@kean.edu
Avinash Parnandi
Department of Computer Science
and Engineering Texas A&M University College Station, TX 29634 avinashparnandi@gmail.com
Dr. Ricardo Gutierrez-Osuna
Department of Computer Science
and Engineering Texas A&M University Clemson, SC 29634 rgutier@cse.tamu.edu
ABSTRACT
heart rate and respiration rate without needing an external sensor. As examples: cardio buddy, What’s my heart rate, Vital Signs Camera. These applications use the front camera to measure the micro color changes of the face produced by every heartbeat to estimate HR and analyze the motion of the chest to compute respiration rate [1,2] These applications require certain amount of light to work properly, under poor lighting conditions they do not work effectively. In order to deal with the issue of variation in ambient lighting, applications such What’s my heart rate, or cardio buddy use as an option the back camera to measure the heart rate using the fingertip over the cellphone’s camera and the flash turned on. However, these apps do not measure respiration rate.
BR measurement is important because it could help subjects to achieve a calm state and to detect and prevent abnormal respiratory rates that may lead to cardiac arrest, stroke and chronic obstructive pulmonary diseases. This study presents an innovative and simple methodology of estimating HR and BR even under poor lighting conditions. The study is based on the effects of respiratory sinus arrhythmia (RSA). That refers to the variation in heart rate when breathing. During inspiration the HR accelerates and during expiration the HR slows down [3]. As well, the principles of PPG. Figure 1 illustrates the effects of RSA using the PPG signal (not filtered) collected from a cellphone’s camera recordings. The peaks under the red line correspond to the heartbeats, and the peaks shaped by the red line are the respiration rate traced by the heart rate over time. The PPG signal was recorded for four minutes at a breathing rate of 6 breaths per minute. The graph clearly shows twenty-four peaks that correspond to the breathing rate. Finally, the results determined the feasibility of extracting HR and BR using a cell phone camera by comparing the measurements acquired using a commercial sensor.
This investigation is divided in two phases. In the first phase, studies were conducted in order to create a proof of concept of the feasibility of extracting HR and BR using an iPhone 4 to record the light absorbance of the finger tissue. The HR is extracted from the PPG signal obtained from the video recordings. Respectively, BR is computed by applying the FFT to the HR data. The data gathered was analyzed using Matlab offline. The second phase, which is still in progress, consist in the implementation of the method on a smartphone application, that can estimate HR and BR in real-time. The method proposed is explained in section 3.3.
The rapid growth of smartphone technology and onboard sensors has enabled non-invasive physiological measurements, which can simplify self and remote assessments. This holds tremendous potential in efficient delivery of health care. This study investigates the feasibility of extracting heart rate (HR) and breathing rate (BR) using a cell phone camera in a non-invasive way, without the need of external sensors and it is independent of ambient lighting condition. The method works by placing the index finger over the cell phone camera and computing the amount of light absorbed by the finger tissue. The phone thus acquires the Photoplethysmographic (PPG) signal. From this HR is estimated by using a peak detection algorithm in order to find the local maxima of the PPG signal and computing the time difference between peaks. We compared the accuracy of HR estimated by our method with a commercial sensor over three different controlled experimental conditions. Here the subject was asked to breath at rate of 6, 10, 12 breaths per minutes (bpm). The results showed a mean error of 0.06, 1.07 and 2.39 bpm under the three settings respectively. We then computed BR from the fast Fourier transform (FFT) of the estimated HR signal. The FFT plots showed a clear harmonic peak at the frequencies, which corresponded to the respective breathing. This study demonstrated an innovative and a simple approach of physiological measurement specifically HR and BR under controlled settings. A mobile application is being developed in order to measure HR and BR. The implementation and results are presented in this study.
1. INTRODUCTION
Current physiological sensing (measuring heart rate, breathing rate and heart rate variability) is commonly done using contact sensors such as chest straps, electrodes or finger clips. However, these sensors are uncomfortable (e.g. finger clip sensors cannot be used while walking and can also restrict activities such as grasping) and introduce additional costs to the users. In addition, users tend to be very concerned with the way sensors affects their appearance or habits; thus, the use of external sensors poses additional usability concerns.
There are some mobile applications in the market that measures
Extracting_SAR_Data_from_the_CD_工学_高等教育_教育专区 暂无评价0人阅读0次下载举报文档 Extracting_SAR_Data_from_the_CD_工学_高等教育_教育专区。SAR ...
Extracting and integrating these objects from the Web is of great signi?cance for Web data management. The existing Web information extraction (IE) ...
We present a new theory of multidimensional AMFM image modeling and derive algorithms for extracting AM-FM sub-image information from digital images. In ...
Extracting Guarantees from T According to the P2P vision, thousands, millions, or even billions of peers may interact in a seething, transient pattern of...
Extracting Knowledge from Biological Descriptions Department of Computer Science and Engineering University of New South Wales Sydney, Australia andrewt@cse.unsw...
Extracting Social Networks from Enron’s Dataset Mengrui Zhu Peizhe Cao Yifan Ding Southeast University Abstract In this paper, we present social network ...
Extracting Oscillation Frequen...
explor a tion r eview EXTRACTING MEANINGFUL INFORMATION FROM SEISMIC ATTRIbUTES Satinder Chopra, Arcis Corporation, Calgary Seismic attributes are a powerful ...
免费 Extracting randomness us... 暂无评价 10页 免费 Randomness Extraction vi... 暂无评价 14页 免费 On extracting randomness... 暂无评价 10页 免费...
Extracting Recursion Operators in Nuprl's Type Theory Abstract. In this paper we describe the extraction of \ecient " recursion schemes from proofs ...
热门文档