Organic Liquids-Responsive β-Cyclodextrin-Functionalized

环糊精改性石墨烯荧光探针在检测有机液体的应用

Molecules 2014, 19, 7459-7479; doi:10.3390/molecules19067459 molecules

ISSN 1420-3049

doc.guandang.net

Article OPEN ACCESS

Organic Liquids-Responsive β-Cyclodextrin-Functionalized Graphene-Based Fluorescence Probe: Label-Free Selective Detection of Tetrahydrofuran

Huawen Hu, John H. Xin *, Hong Hu *, Xiaowen Wang and Xinkun Lu

The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China;

E-Mails: hua.w.hu@connect.polyu.hk (H.H.); wang.xiaowen@polyu.edu.hk (X.W.);

xk.lu@polyu.edu.hk (X.L.)

* Authors to whom correspondence should be addressed; E-Mails: tcxinjh@polyu.edu.hk (J.H.X.); tchuhong@polyu.edu.hk (H.H.); Tel./Fax: +86-852-2766-6474 (J.H.X.).

Received: 1 April 2014; in revised form: 3 June 2014 / Accepted: 4 June 2014 /

Published: 6 June 2014

Abstract: In this study, a label-free graphene-based fluorescence probe used for

detection of volatile organic liquids was fabricated by a simple, efficient and low-cost

method. To fabricate the probe, a bio-based β-cyclodextrin (β-CD) was firstly grafted on

reduced graphene surfaces effectively and uniformly, as evidenced by various

characterization techniques such as Ultraviolet/Visible spectroscopy, Fourier transform

infrared spectroscopy, X-ray diffraction, thermogravimetric analysis, scanning electron

microscopy and transmission electron microscopy. The subsequent inclusion of

Rhodamine B (RhB) into the inner cavities of the β-CD grafted on the graphene surfaces

was achieved easily by a solution mixing method, which yielded the graphene-based

fluorescent switch-on probe. In addition, the gradual and controllable quenching of RhB

by Fluorescence Resonance Energy Transfer from RhB to graphene during the process

of stepwise accommodation of the RhB molecules into the β-CD-functionalized graphene

was investigated in depth. A wide range of organic solvents was examined using the

as-fabricated fluorescence probe, which revealed the highest sensitivity to tetrahydrofuran

with the detection limit of about 1.7 μg/mL. Some insight into the mechanism of

the different responsive behaviors of the fluorescence sensor to the examined targets was

also described.