412OPTICSLETTERS/Vol.36,No.3/February1,2011

High-pressureandhigh-temperaturecharacteristics

ofaFabry–Perot

interferometerbasedonphotoniccrystalfiber

ChuangWu,1,2H.Y.Fu,1KhurramKarimQureshi,3Bai-OuGuan,4andH.Y.Tam1,*

1

PhotonicsResearchCentre,DepartmentofElectricalEngineering,TheHongKongPolytechnicUniversity,HongKong,China

2

3

PolyU-DUTJointResearchCenterforPhotonics,DalianUniversityofTechnology,Dalian116024,China

ElectricalEngineeringDepartment,KingFahdUniversityofPetroleumandMinerals,Dhahran-31261,SaudiArabia

4

InstituteofPhotonicsTechnology,JinanUniversity,Guangzhou510632,China

*Correspondingauthor:eehytam@polyu.edu.hk

ReceivedOctober5,2010;revisedNovember24,2010;acceptedDecember8,2010;

postedJanuary7,2011(Doc.ID136172);publishedJanuary31,2011

Afiber-opticFabry–Perotinterferometerwasconstructedbysplicingashortlengthofphotoniccrystalfibertoastandardsingle-modefiber.ThephotoniccrystalfiberfunctionsasaFabry–Perotcavityandservesasadirectsensingprobewithoutanyadditionalcomponents.Itspressureandtemperatureresponsesintherangeof0–40MPaand25°C–700°Cwereexperimentallystudied.Theproposedsensoriseasytofabricate,potentiallylow-cost,andcompactinsize,whichmakesitveryattractiveforhigh-pressureandhigh-temperaturesensingapplications.©2011OpticalSocietyofAmericaOCIScodes:060.2370,120.2230,060.5295.

AFabry–Pérotinterferometer(FPI)consistsofanopticalcavityformedbytwocloselyspacedmirrors.Multiplere-flectionsbetweenthemirrorsintroducemultiplebeamsthatinterferewitheachother,resultinginaninterferencefringepatterninthespectraldomain.Thefringepatterncanbemodulatedbyexternalperturbationsthatinducechangesineithertherefractiveindexand/orphysicallengthofthecavity,allowingFPIstobeusedinvarioussensingapplications[1].Fiber-opticFPIsensorshavebeenattractingmuchinterestbecausetheyoffermanyoutstandingadvantages,suchashighsensitivity,high-temperaturesurvivability,compactsize,corrosionresis-tance,andimmunitytoelectromagneticinterference[2].Theseadvantagesmakethemverysuitablefordeploy-mentinspace-limitedharshenvironmentssuchasturbineenginesandpowerplantsandintheoilandgasindustry,wherepressureandtemperaturearethetwomostcommonmeasurands[3–7].

Manymethodshavebeendevelopedtofabricatefiber-opticFPIs.Theseincludeusingconventionalhollow-corefiber[3–5],chemicaletching[7,8],andlasermicromachin-ing[9].Recently,FPIsmadefromhollow-corephotonicbandgapfiber[11]andsolid-corephotoniccrystalfiber(PCF)[12]bycleavingandsplicinghavebeende-monstratedasstrainandtemperaturesensors.Theformerneedsacoatingfilmontothefiberendface,therebyin-creasingthecomplexityofthefabricationprocess.Thelatterasatemperaturesensorisnotstable,becausetheairholesareexposedtoexternalenvironment[13].

InthisLetter,wereportafiber-opticFPIconstructedbysplicingasolid-corePCFtoastandardsingle-modefiber(SMF),andtheotherendofthePCFwascollapsedwitharcdischargeusingafusionsplicer.Theentirefab-ricationprocesswasperformedusingacommerciallyavailablefusionsplicer.TheprincipleoftheFPIsensorisalsopresentedhere.Weexperimentallyinvestigatedthehigh-pressureandhigh-temperaturecharacteristicsoftheproposedFPIsensor.Measurementsofpressureupto40MPaandtemperatureupto700°Cwerecarried

0146-9592/11/030412-03$15.00/0

out.ThepressureandtemperaturecoefficientsoftheFPIsensorweremeasuredtobe 5:8pm=MPaand~13pm=°C,respectively.Theexperimentalresultsagreewellwiththetheoreticalanalysis.

Figure1(a)illustratestheexperimentalsetupofourmeasurement.Abroadbandsource(BBS)centeredat1530nmisusedtoilluminatetheFPIthroughanopticalcirculator.ThereflectionspectrumoftheFPIisobservedbyanopticalspectrumanalyzer(OSA).Figures1(b)and1(c)showtheschematicdiagramandphotographofthefabricatedFPI.Ashortlengthofasolid-corePCF(PM-1550-01byBlazePhotonics)wasfirstsplicedtoastan-dardSMFusingthetechniquereportedin[14].BecauseofthesmalldifferenceinrefractiveindexbetweentheSMFandthePCF,amirrorwithrelativelylowreflectivitywasformedatthefiberinterface.ThePCFwasthencleavedtoalengthofseveralmillimeters.Asecondlow-reflectionmirrorattheendofthesolidcorewasformedduetoFrésnelreflection.Asaresult,arelativelyweakFPIwasconstructedwithanintensitycontrastof~6dBasshowninFig.2(a).Toenhancethereflectivityofthesecondmirror,wecollapsedtheairholeswitharcdis-chargeusingafusionsplicer(FurukawaFITEL-S177).TheintensitycontrastoftheFPIincreasedtoabout14dBafterfivearcdischarges,andtheresultsare

OL_High-pressure and high-temperature characteristics of a Fabry–Perot interferometer based on PCF

shown

Fig.1.(Coloronline)(a)Experimentalsetupforthemeasure-ments.(b)SchematicoftheFPIsensorhead.(c)Photographofthe2.1-mm-longFPIsensor.©2011OpticalSocietyofAmerica