文档下载 文档下载导航
设为首页 | 加入收藏
搜索 请输入内容:  
 导航当前位置: 文档下载 > 所有分类 > 自然科学 > 化学 > Optimization by response surface methodology of supercritical carbon dioxide
侵权投诉

Optimization by response surface methodology of supercritical carbon dioxide

H.Xuetal.

LiquorFlavourExtraction

Toextracttheflavourcompoundsremainingintheliquorvinasse,steamdistillation,aSoxhletmethodusingn-hexane,supercriticalcarbondioxideandsubcriticalwaterextractionwereused.

Thevolatilecompoundsinliquorvinassewereextractedbysteamdistil-lation,thestructurewassimilartothatreportedbyYanietal..[11]Tengrammesofliquorvinassewasputinanextractioncolumn,andtheextrac-tionsteam,generatedbyaheatingflask,waspassedthroughthecolumnandcondensed.During2hofextraction,theextractioncolumnwaswrappedwithaheatingtapetomaintainthetemperatureinsidetheextrac-tioncolumnat(105±2)°C.Afterextraction,thecondensedextractwasfur-therextractedwithn-hexaneandconcentratedto2mlwithavacuumrotaryevaporator(ModelR203B,ShanghaiSencoTechnologyCo.Ltd.,Shanghai,China)at40°C.Theextractwaskeptinarefrigeratoruntilanalysis.

InSoxhletextraction,10gofdriedvinassewerewrappedinapaperthimbleandputinaSoxhletextractor.Anappropriatevolume(c.150ml)ofn-hexanewasaddedinaflat-bottomdistillationflask.Theextractionsys-temcomprisedofadistillationflask,aSoxhletextractor,andacoilcon-denserwasheatedat(85±1)°Candrefluxedfor8h.AftertheSoxhletextraction,thesolventcontainingflavourcompoundswasthenconcen-tratedto2mlforanalysis.

AllSC-CO2extractiontrialswerecarriedoutinaHua’ansupercriticalfluidapparatus(ModelHA220-50-06,Nantong,China),whosedescriptionwasgivenextensivelybyXuetal.[12]Aliquotsofgrounddryvinasse(150g)wereputintotheextractionvessel.Eachextractionrunlastedfor2h.Thesepa-ratorIwassetat65°Cand7.5MPawhiletheseparatorIIwassetat35°Cand4–6MPa.TheessentialoilswererecoveredinseparatorI,whereasmostvolatilecomponentswerecollectedinseparatorIIandweighedtoobtaintheextractyield.Theextractionyieldwasexpressedastheratiooftheamountofflavourtotheamountofsample(drybasis)placedintheextrac-tionvessel.

AllthesubcriticalwaterextractionexperimentswerecarriedoutwithonebatchtypeequipmentasdescribedbyHeetal.[13]Aliquots(10g)ofrawma-terialwereloadedintoastainless-steelcylinderfilter(8.0×5.0cmi.d.),withbothendswrappedwith240meshfilters.Afterwords,thecylinderfilterwassealedintotheextractionchamber(300ml),150mlofpreheatedwaterwaspumpedintotheextractionchamberataconstantflowrate(20ml/min)andatthesametimethenitrogenvalvewasopenedtoremovetheoxygenremainedintheextractionsystem.Twominuteslater,thevalvewasclosedtoassureaconstantpressureofwaterremainedasaliquid.Whenthetemper-atureandpressureofthewaterreachedthedesignedvaluesofexperiment,thenitrogenvalvewasshutandtheextractionbegan.Whentheextractionfinished,theoutletvalvewasopened.Theextractswerecollected,cooledandcentrifuged(2850×g10min),andthesupernatantwasstoredat4°Cforfurtheruse.Intheexperiment,extractiontemperaturesweresetfrom90to180°C,andextractiontimeslastedfor60min.Thepressurewassetat5MPatokeepthewaterintheliquidstate.Theratioofliquorvinassepow-der(meshsize40)towaterwas1:10.

vinasse.Theextractionpressure(X1),temperature(X2)andCO2rate(X3)werechosenastheindependentvariables.Preliminaryexperimentswerecarriedouttodeterminethelevelsoftheindependentparameters.Arotat-ablecentralcompositedesignwasselectedtooptimizeprocessvariablesatfivelevelswith20runs,includingsixreplicatesatthecentralpoint.Theex-perimentaldatawerefittedtosecond-orderpolynomialmodels,whichexpressedtheyieldoftotalvolatilecompounds(Y1)andethyl(9Z)-9-octadecenoate(Y2)asafunctionoftheindependentvariablesasfollows:

333XXX

Yn¼a0þaiXiþaiiX2þaijXiXj(1)i

i¼1

i¼1

i≠j

Ynrepresentstheresponsevariables,XiandXjarethelevelsoftheinde-pendentvariables,a0isaconstant,ai,aiiandaijarethelinear,quadratic,and

interactivecoefficients,respectively.Byvaryingtwovariableswithintheex-perimentalrangeandholdingtheotherconstantatthecentralpoint,three-dimensionalsurfaceresponseplotswereobtainedandthecoefficientsoftheresponsesurfaceequationswereestimatedbyDesign-Expert(version8.0.5b)software.Thetestofstatisticalsignificance,basedonthetotalerrorcriteria,withaconfidencelevelof95%(P<0.05)wasdetermined.

GasChromatographyAnalysis

AllanalyseswereperformedonanAgilent6890Ngaschromatograph(GC)equippedwithanAgilent5973massspectrometer(MS).SeparationwasachievedwithanAgilentHP-Innowaxcapillarycolumn(30m×0.25mmi.d.,0.25μmfilmthickness).TheGCinletwasusedinasplitlessmodeandsetat250°C.Theovenwasinitiallysetat50°Cfor5min,thenheatedto100°Cat6°C/min,andheldfor2min,thenraisedto200°Cat8°C/min,andthenincreasedto230°Cat15°C/minandkeptatthistemperaturefor20min.Heliumwasusedascarriergaswithaconstantflowrateof1.0ml/min.Thetransferlinewasmaintainedat280°Candtheionsourcetem-peraturewassetat230°C.Massspectrawereobtainedwithelectronioni-zationat70eVandascanrangefromm/z35to500.Allresultswereexpressedasmeanvaluesofthreeindependentexperiments.IdentificationofthevolatilecompoundswasbasedonGC-MSanalysis.Thecompoundswereidentifiedbycomparingthemassfragmentationpatternsandrelativelinearretentionindex(LRI)withthoseofthereferencecompoundsandtheNIST98andtheWiley7nmassdatabases.Approximatequantitiesofthevolatileswereestimatedbycomparingtheirpeakareaswiththatofthein-ternalstandardacetophenoneusingaresponsefactorof1.

Thecontentofflavourcompound(mg/l)intheextractwascalculatedusingtheformula:

Cx¼

AÂC0ÂV0A0(2)

whereAistheareaofflavourcompoundintheTICchromatogram;C0representstheconcentrationofacetophenone(mg/L);V0isequaltothevolumeofacetophenone(ml);A0istheareaofacetophenone;andVisthevolumeofsample(ml).Themeancoefficientofvariance(CV)ofthreerepetitionsofliquorvinasseextractionforquantitiesofindividualcomponentswas<20%.

OptimizationoftheExtractionParameters

Responsesurfacemethodology(RSM)wasusedtooptimizethesupercriti-calCO2parametersforthemaximumflavourcomponentsextractedfrom

SensoryAssessment

Twentystudents(8malesand12femalesagedbetween21and30years)wererecruitedtoevaluatethesmellpropertiesofextractsfromliquor

Table1.AromaticprofilesofflavourextractsfromliquorvinasseExtractionmethodSteamdistillationSoxhletextractionSC-CO2extraction

a

AromaticprofilesWeakaromaofliquor

StrongliquoraromaticprofileStrongliquoraromaticprofile

Volatilesnumberdetecteda

153455

Parameters

2h

n-hexane85°Cfor8h

30MPa,50°C,CO2rate15l/h,60min

Allthecompoundsweredetectedbygaschromatographycoupledwithmassspectrumanalysis(GC-MS).

wileyonlinelibrary.com/journal/ffjCopyright©2015JohnWiley&Sons,Ltd.FlavourFragr.J.2015