H.Xuetal.
LiquorFlavourExtraction
Toextracttheflavourcompoundsremainingintheliquorvinasse,steamdistillation,aSoxhletmethodusingn-hexane,supercriticalcarbondioxideandsubcriticalwaterextractionwereused.
Thevolatilecompoundsinliquorvinassewereextractedbysteamdistil-lation,thestructurewassimilartothatreportedbyYanietal..[11]Tengrammesofliquorvinassewasputinanextractioncolumn,andtheextrac-tionsteam,generatedbyaheatingflask,waspassedthroughthecolumnandcondensed.During2hofextraction,theextractioncolumnwaswrappedwithaheatingtapetomaintainthetemperatureinsidetheextrac-tioncolumnat(105±2)°C.Afterextraction,thecondensedextractwasfur-therextractedwithn-hexaneandconcentratedto2mlwithavacuumrotaryevaporator(ModelR203B,ShanghaiSencoTechnologyCo.Ltd.,Shanghai,China)at40°C.Theextractwaskeptinarefrigeratoruntilanalysis.
InSoxhletextraction,10gofdriedvinassewerewrappedinapaperthimbleandputinaSoxhletextractor.Anappropriatevolume(c.150ml)ofn-hexanewasaddedinaflat-bottomdistillationflask.Theextractionsys-temcomprisedofadistillationflask,aSoxhletextractor,andacoilcon-denserwasheatedat(85±1)°Candrefluxedfor8h.AftertheSoxhletextraction,thesolventcontainingflavourcompoundswasthenconcen-tratedto2mlforanalysis.
AllSC-CO2extractiontrialswerecarriedoutinaHua’ansupercriticalfluidapparatus(ModelHA220-50-06,Nantong,China),whosedescriptionwasgivenextensivelybyXuetal.[12]Aliquotsofgrounddryvinasse(150g)wereputintotheextractionvessel.Eachextractionrunlastedfor2h.Thesepa-ratorIwassetat65°Cand7.5MPawhiletheseparatorIIwassetat35°Cand4–6MPa.TheessentialoilswererecoveredinseparatorI,whereasmostvolatilecomponentswerecollectedinseparatorIIandweighedtoobtaintheextractyield.Theextractionyieldwasexpressedastheratiooftheamountofflavourtotheamountofsample(drybasis)placedintheextrac-tionvessel.
AllthesubcriticalwaterextractionexperimentswerecarriedoutwithonebatchtypeequipmentasdescribedbyHeetal.[13]Aliquots(10g)ofrawma-terialwereloadedintoastainless-steelcylinderfilter(8.0×5.0cmi.d.),withbothendswrappedwith240meshfilters.Afterwords,thecylinderfilterwassealedintotheextractionchamber(300ml),150mlofpreheatedwaterwaspumpedintotheextractionchamberataconstantflowrate(20ml/min)andatthesametimethenitrogenvalvewasopenedtoremovetheoxygenremainedintheextractionsystem.Twominuteslater,thevalvewasclosedtoassureaconstantpressureofwaterremainedasaliquid.Whenthetemper-atureandpressureofthewaterreachedthedesignedvaluesofexperiment,thenitrogenvalvewasshutandtheextractionbegan.Whentheextractionfinished,theoutletvalvewasopened.Theextractswerecollected,cooledandcentrifuged(2850×g10min),andthesupernatantwasstoredat4°Cforfurtheruse.Intheexperiment,extractiontemperaturesweresetfrom90to180°C,andextractiontimeslastedfor60min.Thepressurewassetat5MPatokeepthewaterintheliquidstate.Theratioofliquorvinassepow-der(meshsize40)towaterwas1:10.
vinasse.Theextractionpressure(X1),temperature(X2)andCO2rate(X3)werechosenastheindependentvariables.Preliminaryexperimentswerecarriedouttodeterminethelevelsoftheindependentparameters.Arotat-ablecentralcompositedesignwasselectedtooptimizeprocessvariablesatfivelevelswith20runs,includingsixreplicatesatthecentralpoint.Theex-perimentaldatawerefittedtosecond-orderpolynomialmodels,whichexpressedtheyieldoftotalvolatilecompounds(Y1)andethyl(9Z)-9-octadecenoate(Y2)asafunctionoftheindependentvariablesasfollows:
333XXX
Yn¼a0þaiXiþaiiX2þaijXiXj(1)i
i¼1
i¼1
i≠j
Ynrepresentstheresponsevariables,XiandXjarethelevelsoftheinde-pendentvariables,a0isaconstant,ai,aiiandaijarethelinear,quadratic,and
interactivecoefficients,respectively.Byvaryingtwovariableswithintheex-perimentalrangeandholdingtheotherconstantatthecentralpoint,three-dimensionalsurfaceresponseplotswereobtainedandthecoefficientsoftheresponsesurfaceequationswereestimatedbyDesign-Expert(version8.0.5b)software.Thetestofstatisticalsignificance,basedonthetotalerrorcriteria,withaconfidencelevelof95%(P<0.05)wasdetermined.
GasChromatographyAnalysis
AllanalyseswereperformedonanAgilent6890Ngaschromatograph(GC)equippedwithanAgilent5973massspectrometer(MS).SeparationwasachievedwithanAgilentHP-Innowaxcapillarycolumn(30m×0.25mmi.d.,0.25μmfilmthickness).TheGCinletwasusedinasplitlessmodeandsetat250°C.Theovenwasinitiallysetat50°Cfor5min,thenheatedto100°Cat6°C/min,andheldfor2min,thenraisedto200°Cat8°C/min,andthenincreasedto230°Cat15°C/minandkeptatthistemperaturefor20min.Heliumwasusedascarriergaswithaconstantflowrateof1.0ml/min.Thetransferlinewasmaintainedat280°Candtheionsourcetem-peraturewassetat230°C.Massspectrawereobtainedwithelectronioni-zationat70eVandascanrangefromm/z35to500.Allresultswereexpressedasmeanvaluesofthreeindependentexperiments.IdentificationofthevolatilecompoundswasbasedonGC-MSanalysis.Thecompoundswereidentifiedbycomparingthemassfragmentationpatternsandrelativelinearretentionindex(LRI)withthoseofthereferencecompoundsandtheNIST98andtheWiley7nmassdatabases.Approximatequantitiesofthevolatileswereestimatedbycomparingtheirpeakareaswiththatofthein-ternalstandardacetophenoneusingaresponsefactorof1.
Thecontentofflavourcompound(mg/l)intheextractwascalculatedusingtheformula:
Cx¼
AÂC0ÂV0A0(2)
whereAistheareaofflavourcompoundintheTICchromatogram;C0representstheconcentrationofacetophenone(mg/L);V0isequaltothevolumeofacetophenone(ml);A0istheareaofacetophenone;andVisthevolumeofsample(ml).Themeancoefficientofvariance(CV)ofthreerepetitionsofliquorvinasseextractionforquantitiesofindividualcomponentswas<20%.
OptimizationoftheExtractionParameters
Responsesurfacemethodology(RSM)wasusedtooptimizethesupercriti-calCO2parametersforthemaximumflavourcomponentsextractedfrom
SensoryAssessment
Twentystudents(8malesand12femalesagedbetween21and30years)wererecruitedtoevaluatethesmellpropertiesofextractsfromliquor
Table1.AromaticprofilesofflavourextractsfromliquorvinasseExtractionmethodSteamdistillationSoxhletextractionSC-CO2extraction
a
AromaticprofilesWeakaromaofliquor
StrongliquoraromaticprofileStrongliquoraromaticprofile
Volatilesnumberdetecteda
153455
Parameters
2h
n-hexane85°Cfor8h
30MPa,50°C,CO2rate15l/h,60min
Allthecompoundsweredetectedbygaschromatographycoupledwithmassspectrumanalysis(GC-MS).
wileyonlinelibrary.com/journal/ffjCopyright©2015JohnWiley&Sons,Ltd.FlavourFragr.J.2015
Supercritical fluid extr... 暂无评价 21页 2财富值 Optimization of microwav....response surface methodology for optimising supercritical carbon dioxide extraction...
3): 203-209.(SCI) 7、 Optimization of process parameters for supercritical carbon dioxide extraction of Passiflora seed oil by response surface methodology....
Use of response surface methodology for optimization_医药卫生_专业资料。木糖醇Journal of Food Engineering 76 (2006) 376–386 www.elsevier.com/locate/jfooden...
05_Response Surface Methodology_计算机硬件及网络_IT/计算机_专业资料。Response ...Use the model for optimization purposes and confirm results 第三步:利用该模型...
RESPONSE SURFACE METHODOLOGY (RSM)_医药卫生_专业资料。14.0 RESPONSE SURFACE ...RSM: An experimental optimization procedure: 1. Plan and run a factorial (...
响应面法 Optimization of the Supercritical Fluid ...by Response Surface Methodology WANG Da-wei, ZHOU...Supercritical carbon dioxide extraction was applied ...
Optimization of Supercritical Carbon Dioxide Extraction of Flaxseed Oil Using Response Surface Methodology [J ].International Journal of Food Engineering ,2008 ...
Thus, optimization of the growth medium for biosurfactant-lichenysin production by Bacillus licheniformis R2 was carried out using response-surface methodology....
Optimization of Supercritical Carbon Dioxide Extraction Li Maoqian1, Hu Ping...ora seed oil by response surface methodology[J].The Journal of Supercritical...
Effect of various carbon and nitrogen sources on protease production by ...Optimization by response surface methodology. The results of FCCCD experiments ...
THE RESPONSE SURFACE METHODOLOGY_工学_高等教育_教育...optimization, it makes sense to use a rotatable ...(F), and Carbon (G); the remaining two are ...
关键词:蜂胶;超临界二氧化碳;响应面 Optimization of Supercritical Carbon Dioxide Extraction of Effective Components from Propolis Using Response Surface Methodology ...
热门文档