The inulin hydrogen breath test accurately reflects orocaecal transit time

2007 Oct;37(10):802-7. Epub 2007 Aug 28.

The inulin hydrogen breath test accurately reflects orocaecal transit time.

, , , , .

Source

Hospital of the J.W. Goethe-University, Frankfurt, Germany. arne.schneider@em.uni-frankfurt.de Abstract BACKGROUND:

The lactose[(13)C]ureide breath test ((13)C-LUBT) has been validated and established as a reliable, non-invasive test for the assessment of orocaecal transit time (OCTT). More recently, small studies have demonstrated that inulin could be an alternative substrate for H(2)-based breath testing of the small bowel transit (H(2)-INBT). We compared the performance of the H(2)-INBT with the (13)C-LUBT in an appropriate number of participants, determined by sample-size calculation.

DESIGN:

Twenty-nine people underwent a combined (13)C-LUBT/H(2)-INBT. Five Hundred mg of

lactoseureide was ingested on the day before the test to induce an adequate enzyme activity in colonic bacteria. For the test, they received 500 mg of lactose[(13)C]ureide and 5 g inulin,

dissolved in 400 mL of a standard enteral liquid nutrition orally. Breath samples were collected every 30 min for 8 h and analysed for H(2)[ p.p.m.] and (13)CO(2)-enrichment [delta-(13)C]. For the (13)C-LUBT, the OCTT was defined as the interval with an increase of delta > 2.5SD above the running average of all previous points. The latter was defined as a rise of > 10ppm above baseline regarding the H(2)-INBT.

RESULTS:

Breath tests produced evaluable data in 27/29 patients [93%]. Median OCTTs were 315 min

(range 210-450 min) for the (13)C-LUBT and 300 min (180-420 min) for the H(2)-INBT (P = 0.15). The (13)C-LU-OCTT correlated well with the H(2)-IN-OCTT (r = 0.72). Bland-Altman blot showed that the mean H(2)-IN-OCTTs were approximately 30 min shorter than predicted with the (13)C-LUBT.

CONCLUSIONS:

Inulin is a reliable and inexpensive substrate for a hydrogen-based assessment of the OCTT. In contrast to the (13)C-LUBT, the H(2)-INBT does not require patients to refrain from physical activity and may additionally increase its acceptance for clinical purposes.

第1页

你可能喜欢

热门文档

相关文档

  • Inulin is an ideal substrate

    doi: 10.1046/j.1365-2036.2003.01750.x Inulin is an ideal substrate for a hydrogen breath test to measure the orocaecal transit time K. P. GEBOES,...

  • What is the hydrogen breath test

    The inulin hydrogen brea... 暂无评价 1页 免费...To diagnose bacterial overgrowth and rapid transit ...are not able to accurately culture the samples. ...

  • 氢呼气试验文献整理

    L,?et?al.?The?inulin?hydrogen?breath?test?accurately?reflects?orocaecal?transit?time.?Eur?J?Clin?Invest.?2007?Oct;37(10):802-7.?Epub?2007?Aug?28...

  • What is the hydrogen breath test

    The inulin hydrogen brea... 暂无评价 1页 免费...To diagnose bacterial overgrowth and rapid transit ...are not able to accurately culture the samples. ...

站点地图 | 文档上传 | 侵权投诉 | 手机版
本站所有资源均来自互联网,本站只负责收集和整理,均不承担任何法律责任,如有侵权等其它行为请联系我们.
文档下载 Copyright 2013 doc.guandang.net All Rights Reserved.  -  email