文档下载 文档下载导航
设为首页 | 加入收藏
搜索 请输入内容:  
 导航当前位置: 文档下载 > 所有分类 > 工程科技 > 环境科学/食品科学 > Unit 32 Monitoring Air Quality in Mountains
侵权投诉

Unit 32 Monitoring Air Quality in Mountains

专业英语

which is a partial barrier to low-a1titude atmospheric transport.Samplers were located at constant elevations between transects to the greatest extent possible, and were CO—located with continuous analyzers at two sites-Samplers were collected concurrently along each transect at weekly intervals during the summer of 1994 and 1995.

Monitoring at the watershed scale focused On the Nisqually River drainage within and to the west of Mount Rainier National Park.Passive samplers were located along a single transect within the drainage,and were co-located with continuous analyzers at two sites. Samplers were collected at weekly intervals during the summers of 1994 through 1997. This effort was inclusive of samples collected as part of regional and subregional-scale sampling in 1994 through 1996 as described above.

3.Statistical Analysis

Weekly average ozone exposures were calculated for each passive sampler site.Ozone exposures were plotted for each transect to detect temporal variation in ozone concentrations with elevation. A seasonal was calculated from the weekly average ozone exposures for each site to compare differences in ozone concentrations at same elevations.

We wanted to know if ozone concentrations were the same at similar elevations between transects and if the ozone-elevation trend was the same in each transect.Averages for the en-tire sampling period were calculated for each transect in the regional, subregional, and watershed monitoring schemes.Residual analysis indicates that passive sampler data are normally distributed.Therefore,analysis of covariance③ was used to test for significant differences (at = 0.05) among treatment groups.Simple linear regression was used to develop models that describe the ozone-elevation relationship observed in the data.E1evation and transect were used in the model as independent variables, and differences between treatments were determined by testing for differences in slope and intercept④.

In the regional-scale study, spatial and temporal coherence⑤ in ozone concentrations among transects was examined with a permutation test for synchrony,where synchrony is defined as the tendency of ozone measured at same-elevation sites to vary similarly between sequential weekly measurements.We examined the direction of change(higher of lower ozone values) between weeks at sites with elevation.Values of change were encoded as +1 (positive change from previous week),0 (no change from previous week),and -1 (negative change previous week).These numbers were run against 10000 trials with randomized data.The null hypothesis was that values of change are randomly arranged at all sites.A p-statistic expressed the probability of data representing a nonsynchronous set of events.

Notes

①if the spatial representativeness of monitoring sites has not been previously determined within the context of a coordinated network,the data may not be useful for inferences at large spatial scale.可译为:如果在一个协调的监控系统中没有预先确定监控位置的代表 性空间分布,则所得的数据要在大的空间范围内进行推断就没用了。

②Sites were generally matched in elevation between transects to facilitate spatial comparison of measurement.可译为:取样位置一般和各横断面间的海拔相对应,

上一页第3页

你可能喜欢

热门文档

相关文档

  • Monitoring air quality

    MONITORING AIR QUALITY NOx (NO & NO2) contents measured in Kauppatori and Puistokatu areas of Turku in Year 1997, according to wind direction, rhythm ...

  • 3095-96-Ambient Air Quality Standard

    according to different monitoring reasons 8.3 Ambient air quality function areas should be classified by the Environmental Protection Bureau above local level...

  • Indoor–outdoor air quality relationships in vehicle

    Indoor–outdoor air quality relationships in vehicle_英语学习_外语学习_教育...own research with this kind of monitoring equipment as in Spengler et al....

  • Evaluation_of_ambient_air_quality___in_Guangzhou__C...

    air quality index (API) and air pollutant monitoring data provided by the Guangzhou Environment Monitoring Stations over the last twenty-ve years, the ...

  • 8 Air Quality Issues

    Air Quality Permit 47页 2财富值 Monitoring air quality 10页 2财富值 AIR... Ozone Peroxyacetyl Nitrates Large cities ringed by mountains tend to have ...

  • 绪论

    (3学时) 7.Unit six:Summary of Environmental Impact Assessment; 学术交流 信件写作 (3学时) 8.Unit seven: Monitoring Air Quality in Mountains-Designing(3...

  • 一个自动化网络系统的空气质量监测

    ?ega * * Institute for Medical Research and Occupational Health / Unit of... there is an institution responsible for monitoring air quality in each ...

  • 英文给排水专业术语

    air quality monitoring air quality monitoring network air quality monitoring ...air-cooled condenser fan air-cooled condensing unit aircraft engine ground ...

  • AIR POLLUTION IN BEIJING

    monitoring station says are 'Hazardous' levels in Beijing on December 5, ...Poor air quality in Beijing, and the way it's reported by government ...

  • 机动车污染控制

    Air quality in Macao 澳门交通环境颗粒物浓度的空间分布监测 Monitoring of ... the unit of black figures are kg/kL, while kg/TJ for red and kg/t...

站点地图 | 文档上传 | 侵权投诉 | 手机版
本站所有资源均来自互联网,本站只负责收集和整理,均不承担任何法律责任,如有侵权等其它行为请联系我们.
文档下载 Copyright 2013 doc.guandang.net All Rights Reserved.  -  email