Engineering Recommendations and Minimum Standard
The below is not deemed to supersede or override any comments, approvals or compliance with prevailing codes and legal requirements issued by authorities having jurisdiction over the project provided that such codes are demonstrably higher than the minimum standards contained herein.
Minimum velocity of 1.2 m/sec from all Kitchen areas to convey greasy water. Minimally provide airtight seals to interceptor housings. All grease interceptors shall be powered, heated and fully automatic skimming type. Adequate ventilation shall be provided.
Floor Drains shall be equipped with flush mounted removable grills with frames recessed and sealed into a suitably prepared floor. Finish to be approved by the Interior Designer or Architect.
All floor drains subjected to infrequent flow are to be provided with a trap primer to maintain a water seal against odors and gases.
Other than Kitchens, are Floor Drains required in the following areas? Receiving dock and garbage handling?
All Pantries?
All Bar Station?
3rd Floor Silk Road Service Bar?
Ground Floor Walk-in Cold Rooms and Storage Rooms.?
Design Parameters