JournalofChromatographyA,1148(2007)

145–151
Liquid-phasemicroextraction–gaschromatography–massspectrometryforthedeterminationofbromate,iodate,
bromideandiodideinhigh-chloridematrix
KishanReddy-Noone,ArchanaJain,KrishnaK.Verma
DepartmentofChemistry,RaniDurgavatiUniversity,Jabalpur482001,MadhyaPradesh,IndiaReceived24December2006;receivedinrevisedform5March2007;accepted7March2007
Availableonline16March2007
Abstract
Inthedeterminationofbromateandiodate,anyfreebromideandiodidepresentwasquantitativelyremovedbyanionexchangewithsilverchlorideexploitingthedifferencesinsilversaltssolubilityproduct,beingAgCl,1.8×10 10,AgBr,5.0×10 13,AgI,8.3×10 17,AgBrO3,5.5×10 5andAgIO3,3.1×10 8.Theoxyhalideswerereducedwithascorbicacidtohalidesandconvertedto4-bromo-2,6-dimethylanilineand4-iodo-2,6-dimethylanilinebytheirreactionwith2-iodosobenzoateinthepresenceof2,6-dimethylanilineatpH6.4and2–3,respectively.Singledropmicroextraction(SDME)ofthehaloanilinesin2 loftolueneandinjectionofthewholeextractintoGC–MS,orliquid-phasemicroextraction(LPME)into50 loftolueneandinjectionof2 lofextract,resultedinasensitivemethodforbromateandiodate.Thelattermethodofextractionhasbeenfoundmorerobust,sensitiveandtogivebetterextractioninshorterperiodthanSDME.Totalbromine/iodinewasdeterminedwithoutanytreatmentwithsilverchloride.Highconcentrationofchlorideinthematrixdidnotinterfere.Arectilinearcalibrationgraphwasobtainedfor0.05 g–25mgl 1ofbromate/bromideandiodate/iodide,thelimitofdetectionwere20ngl 1ofbromate,15ngl 1ofiodate,20ngl 1ofbromideand10ngl 1ofiodide(byLPMEin50 loftoluene).Themethodhasbeenappliedtoseawaterandtablesalt.Fromthepooleddata,theaveragerecoveryofspikedoxyhalide/halidetorealsampleswasinrange96.7–105.7%withRSDinrange1.6–6.5%.
©2007PublishedbyElsevierB.V.
Keywords:Bromate;Iodate;Iodide;Bromide;High-chloridematrix;Liquid-phasemicroextraction;Singledropmicroextraction;Gaschromatography–massspectrometry
1.Introduction
Ontheoccurrenceofhighamountsinenvironmentalsamples,bromiderepresentsahazardtopublichealth[1,2].Long-termelevateddietarylevelsofbromideexertchangesonthestatusofthethyroidgland,witheventualsubstitutionofiodidebybro-mideduringbiosynthesisofthyroidhormones[3,4].Brominatedandiodinatedcompoundsareproducedduringthedisinfectionofwaterbychlorineinthepresenceofbromideandiodide[5,6].Toxicologicalstudiessuggestthatbrominatedandiod-inatedcompoundsmaybemorecarcinogenicthanchlorinatedanalogues[7].Ozone,usedasanalternativedisinfectanttochlo-rine,generatesbromateasaby-productinwaterscontainingthe
Correspondingauthor.Tel.:+917612678103;fax:+917612403252.E-mailaddress:arichna@sancharnet.in(K.K.Verma).
precursorbromide.Bromatehasbeenclassi edasagroup2Bprobablehumancarcinogen[8].In1993,theWHOsetalimitof25 gl 1forbromateindrinkingwater[9].Despitethehealthrisks,thisguidelinewasbasedonthelimitationsofthemeasure-menttechniquesforbromate.TheUSEnvironmentalProtectionAgency(EPA)setamaximumcontaminantlevelof10 gl 1bromateunderStage1Disinfectants/DisinfectionByproductsRulein1998[10].TheEUreducedtheirregulatoryvaluefrom50to10 gl 1bromateindrinkingwater[11]andtheWHOalsosetaguidelineof10 gl 1[12].Acancerriskof1in105hasbeenassessedat0.5 gl 1bromatebasedoningestionofdrinkingwater[13].
Ionchromatographyhasbeentraditionallyusedfordeter-miningbromate,otheroxyhalidesandhalidesusingacarbonateeluentandsuppressedconductivitydetection[14].Ahydroxideeluenthasbeenfoundtohavelowersup-pressedbackgroundconductivity[15].Preconcentrationbefore
0021-9673/$–seefrontmatter©2007PublishedbyElsevierB.V.doi:10.1016/j.chroma.2007.03.027
c o m / l o c a t e / m i c r o c Development of a headspace solid-phase microextraction/gas chromatography–mass spectrometry method for ...
extraction and derivatization liquid-phase microextraction for the determination of chlorophenols by gas chromatography–mass spectrometry Xiaowei Wang a , Lijuan ...
Gas chromatography–mass spectrometry(GC-MS)_化学_自然科学_专业资料。Gas ... Liquid microextraction... 暂无评价 34页 免费 An overview of matrix ......
Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for Determ_专业资料。D C D JCeCeEg521)- .hm.hm.n.(0 161……镊 ...
气相色谱仪-质谱 Applied the method of headspace liquid-phase micro-extraction coupled with gas chromatography-mass spectrometry to the determination of phenols...
Solid—phasemicroextraction;Gaschromatography-massspectrometry(Reeeived15April2011l accepted20 June2011) 万方数据 固相微萃取-气相色谱-质谱联用测定水中痕量2-甲基...
Odetokun, “Liquid Chromatography Mass Spectrometer (LC-MS/MS) Study of ...Spectrometry Coupled with Solid Phase Extraction,” Chinese Journal of ...
Key word: headspace liquid-phase micro-extraction(HS-LPEM) ; wines ; ethyl carbamate ; gas chromatography-mass spectrometry(GC-MS) 氨基甲酸乙酯(Ethyl ...
liquid-phase microextraction and gas chromatography–mass spectrometry[J].Journal of Chromatography A,2008,(1204):119-122. [12]A . Prieto , O . Zuloaga...
Verma. Single drop microextraction or solid phase microextraction–gas chromatography–mass spectrometry for the determination of iodine in pharmaceuticals, ...
热门文档