文档下载 文档下载导航
设为首页 | 加入收藏
搜索 请输入内容:  
 导航当前位置: 文档下载 > 所有分类 > 工程科技 > 机械/仪表 > update stiffness的选用
侵权投诉

update stiffness的选用


Normal Stiffness Factor: Allows input of the Normal Stiffness Factor. Only positive values
are allowed. This choice is displayed only if Manual is specified for Normal Stiffness.

Update Stiffness: Allows you to specify if the program should update (change) the contact
stiffness during the solution. The update choices are listed below. If you choose any of
these stiffness update settings, the program will modify the stiffness (raise/lower/leave
unchanged) based on the physics of the model (that is, the underlying element stress and
penetration). This choice is displayed only if you set the Formulation to Augmented
Lagrange or Pure Penalty, the two formulations where contact stiffness is applicable.
An advantage of choosing either of the program stiffness update settings is that
stiffness is automatically determined that allows both convergence and minimal penetration. Also,
if this setting is used, problems may converge in a Newton-Raphson sense, that would not otherwise.
You can use a Result Tracker to monitor a changing contact stiffness throughout
the solution.
Never: (Default)1 Turns off the program's automatic Update Stiffness feature.
Each Equilibrium Iteration: Sets the program to update stiffness at the end of each
equilibrium iteration. This choice is recommended if you are unsure of a Normal
Stiffness Factor to use in order to obtain good results.
Each Equilibrium Iteration, Aggressive: Sets the program to update stiffness at
the end of each equilibrium iteration, but compared to the Each Equilibrium Iteration,
this option allows for a more aggressive changing of the value range.

1 - The default can be changed in the Options dialog box under Connections.

第1页

你可能喜欢

热门文档

相关文档

  • Tooth Meshing Stiffness Optimisation

    update stiffness的选用 暂无评价 1页 1财富值 2.1 Stiffness Matrix 24页 免费 Reduced Stiffness Matrix 4页 1财富值 A Contact Stiffness Mode... 7页 ...

  • Stiffness modeling of RC columns reinforced with pl...

    ASCE/SEI 41 update report (Elwood et al. 2007) states that lower effective stiffness values might be attained for the structural components with plain ...

  • workbench中文

    (按名称选择) 5.Material Properties(材料属性) 四、Advanced Geometry Options ...(从接触结点预计正常) 3.Normal Stiffness(法向刚度) 4.Update Stiffness(更新...

  • 0810G-update

    by what1949@newsmth Please visit: GRE@newsmth Last Update: 10/26/2008 11...(E) recondite : stiffness 15、VERIFICATION : ACCURACY (A) amplification : ...

  • workbench瞬态分析—脚轮冲击

    10. 选择和确认冲击块底部的面作为接触面“Contact”. ? 将“Update Stiffness” 改变为“Each Equilibrium Iteration” 9 July 10, 2007 ? 2007 ANSYS, Inc....

  • Brian-Murine ACL update-2014

    Brian-Murine ACL update-2014_临床医学_医药卫生_专业资料。ACL reconstruction...Mean failure force – 1.50 ?Mean stiffness – 5.40N (SD 2.33) ?...

  • GTS NX主要分析功能介绍

    Update stiffness and residual(K i , f i ) thread0 Update stiffness and...[体积含水率函数] 14 部分饱和岩土特性的使用选项→ 在材料特性中选择非饱和...

  • Chapter13 Nonlinear Simulations

    ? ? ? Pinball Region Interface Treatment Time Step Controls Update Stiffness Chapter 13 Nonlinear Simulations Section 13.1 Basics of Nonlinear Simulations 3 ...

  • cdc-webinar-meningitis-update-12-20

    CDC Webinar: Update on the Multistate Outbreak of Fungal Meningitis and ... neck stiffness, chills, and fatigue 15 days after injection Lumbar puncture...

  • AWB120_Dynamics_W06A_Transient ansys

    – >Insert>Manual Contact Region – Use Face select – Change “Update Stiffness” to “Each Equilibrium Iteration” Training Manual 8 ANSYS, Inc. ...

站点地图 | 文档上传 | 侵权投诉 | 手机版
本站所有资源均来自互联网,本站只负责收集和整理,均不承担任何法律责任,如有侵权等其它行为请联系我们.
文档下载 Copyright 2013 doc.guandang.net All Rights Reserved.  -  email