NIH Public Access Author Manuscript J Magn Reson Imaging. Author manuscript; available in PMC 2013 June 01. Published in final edited form as: J Magn Reson Imaging. 2012 June; 35(6): 1356–1364. doi:10.1002/jmri.23585.
Accuracy of MR Elastography and Anatomic MR Imaging Features in the Diagnosis of Severe Hepatic Fibrosis and Cirrhosis Rahul Rustogi, MD1, Jeanne Horowitz, MD1, Carla Harmath, MD1, Yi Wang, MD1,2, Hamid Chalian, MD1, Daniel R. Ganger, MD3, Zongming E. Chen4, Bradley D Bolster Jr, PhD5, Saurabh Shah, PhD6, and Frank H. Miller, MD1 1Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, Illinois, United States 2Beijing
$watermark-text$watermark-text$watermark-text
University People’s Hospital, Radiology Department. Xizhimen South St. 11 Xicheng Beijing China 10004 3Northwestern
Memorial Hospital, Northwestern University Feinberg School of Medicine, Department of Medicine, Hepatology Division, Chicago, Illinois, United States 4Northwestern
Memorial Hospital, Northwestern University Feinberg School of Medicine, Department of Pathology, Chicago, Illinois, United States 5Siemens 6Siemens
Healthcare, 200 First St. S.W. Rochester, MN 55905. USA Healthcare, 737 N Michigan Avenue, Suite 1600. Chicago, IL 60611. USA
Abstract Purpose—To compare the diagnostic accuracy of MR elastography and anatomic MR imaging features in the diagnosis of severe hepatic fibrosis and cirrhosis. Materials and Methods—Three readers independently assessed presence of morphological changes associated with hepatic fibrosis in 72 patients with liver biopsy including: caudate to right lobe ratios, nodularity, portal venous hypertension (PVH) stigmata, posterior hepatic notch, expanded gallbladder fossa and right hepatic vein caliber. Three readers measured shear stiffness values using quantitative shear stiffness maps (elastograms). Sensitivity, specificity and diagnostic accuracy of stiffness values and each morphological feature were calculated. Inter-reader agreement was summarized using weighted kappa statistics. Intra-class correlation coefficient was used to assess inter-reader reproducibility of stiffness measurements. Binary logistic regression was used to assess inter-reader variability for dichotomized stiffness values and each morphological feature. Results—Using 5.9 kPa as a cut-off for differentiating F3–F4 from F0–2 stages, overall sensitivity, specificity and diagnostic accuracy for MR elastography were 85.4%, 88.4% and 87% respectively. Overall inter-reader agreement for stiffness values was substantial, with insignificant difference (p=0.74) in the frequency of differentiating F3–4 from F0–2 fibrosis. Only hepatic nodularity and PVH stigmata showed moderately high overall accuracy of 69.4% and 72.2%. Inter-reader agreement was substantial only for PVH stigmata, moderate for C/R m, deep notch and expanded gallbladder fossa. Only posterior hepatic notch (p=0.82)
showed no significant difference in reader rating. Corresponding author: Frank H. Miller, MD, Chief, Body Imaging Section, Medical Director MR Imaging, Department of Radiology, Northwestern University Feinberg School of Medicine, 676 N. St. Clair, Suite 800, Chicago Illinois 60611 USA, Tel: 312-695-3775, Fax: 312-695-5645, fmiller@northwestern.edu.

015 2011A feasibility study of MR elastography ...imaging have demonstrated improved accuracy in the ...anatomic information provided by MRI through ...
and Anatomic Pathology (L.J.B.), Mayo Clinic,...IMAGING: MR Elastography of the Liver Rouvie `re... 011 2012Accuracy of MR... 013 2008MR ...
015 2011A feasibility study of MR elastography ...imaging have demonstrated improved accuracy in the ...anatomic information provided by MRI through ...