ASTM A435-A435M-90

Designation:A435/A435M–90(Reapproved2001)
StandardSpeci cationfor
Straight-BeamUltrasonicExaminationofSteelPlates1
Thisstandardisissuedunderthe xeddesignationA435/A435M;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginaladoptionor,inthecaseofrevision,theyearoflastrevision.Anumberinparenthesesindicatestheyearoflastreapproval.Asuperscriptepsilon(e)indicatesaneditorialchangesincethelastrevisionorreapproval.
1.Scope
1.1Thisspeci cation2coverstheprocedureandacceptancestandardsforstraight-beam,pulse-echo,ultrasonicexamina-tionofrolledfullykilledcarbonandalloysteelplates,1 2in.[12.5mm]andoverinthickness.Itwasdevelopedtoassuredeliveryofsteelplatesfreeofgrossinternaldiscontinuitiessuchaspipe,ruptures,orlaminationsandistobeusedwhenevertheinquiry,contract,order,orspeci cationstatesthattheplatesaretobesubjectedtoultrasonicexamination.1.2Individualsperformingexaminationsinaccordancewiththisspeci cationshallbequali edandcerti edinaccordancewiththerequirementsofthelatesteditionofASNTSNT-TC-1Aoranequivalentacceptedstandard.Anequivalentstandardisonewhichcoversthequali cationandcerti cationofultrasonicnondestructiveexaminationcandidatesandwhichisacceptabletothepurchaser.
1.3Thevaluesstatedineitherinch-poundunitsorSIunitsaretoberegardedseparatelyasstandard.Withinthetext,theSIunitsareshowninbrackets.Thevaluesstatedineachsystemarenotexactequivalents,therefore,eachsystemmustbeusedindependentlyoftheother.Combiningvaluesfromthetwosystemsmayresultinnonconformancewiththespeci -cation.
2.ReferencedDocuments2.1ASNTStandard:
SNT-TC-1ARecommendedPracticeforPersonnelQuali -cationandCerti cationinNondestructiveTesting3
3.Apparatus
3.1Themanufacturershallfurnishsuitableultrasonicequipmentandquali edpersonnelnecessaryforperformingthetest.Theequipmentshallbeofthepulse-echostraightbeamtype.Thetransducerisnormally1to11 8in.[25to30mm]indiameteror1in.[25mm]square;however,anytransducerhavingaminimumactiveareaof0.7in.2[450mm2]maybe
used.Thetestshallbeperformedbyoneofthefollowingmethods:directcontact,immersion,orliquidcolumncoupling.3.2Othersearchunitsmaybeusedforevaluatingandpinpointingindications.
4.TestConditions
4.1Conducttheexaminationinanareafreeofoperationsthatinterferewithproperfunctioningoftheequipment.
4.2Cleanandsmooththeplatesurfacesufficientlytomaintainareferencebackre ectionfromtheoppositesideoftheplateatleast50%ofthefullscaleduringscanning.
4.3Thesurfaceofplatesinspectedbythismethodmaybeexpectedtocontainaresidueofoilorrustorboth.Anyspeci edidenti cationwhichisremovedwhengrindingtoachievepropersurfacesmoothnessshallberestored.5.Procedure
5.1Ultrasonicexaminationshallbemadeoneithermajorsurfaceoftheplate.Acceptanceofdefectsincloseproximitymayrequireinspectionfromthesecondmajorsurface.Platesorderedinthequenchedandtemperedconditionshallbetestedfollowingheattreatment.
5.2Anominaltestfrequencyof21 4MHzisrecommended.Thickness,grainsize,ormicrostructureofthematerialandnatureoftheequipmentormethodmayrequireahigherorlowertestfrequency.However,frequencieslessthan1MHzmaybeusedonlyonagreementwiththepurchaser.Aclear,easilyinterpretedtracepatternshouldbeproducedduringtheexamination.
5.3Conducttheexaminationwithatestfrequencyandinstrumentadjustmentthatwillproduceaminimum50toamaximum75%offullscalereferencebackre ectionfromtheoppositesideofasoundareaoftheplate.Whilecalibratingtheinstrument,sweepthecrystalalongtheplatesurfaceforadistanceofatleast1Tor6in.[150mm],whicheveristhegreater,andnotethepositionofthebackre ection.Ashiftinlocationofthebackre ectionduringcalibrationshallbecauseforrecalibrationoftheinstrument.
5.4Scanningshallbecontinuousalongperpendiculargridlinesonnominal9-in.[225-mm]centers,oratthemanufac-turer’soption,shallbecontinuousalongparallelpaths,trans-versetothemajorplateaxis,onnominal4-in.[100-mm]centers,orshallbecontinuousalongparallelpathsparalleltothemajorplateaxis,on3-in.[75-mm]orsmallercenters.A
Thisspeci cationisunderthejurisdictionofASTMCommitteeA-1onSteel,StainlessSteel,andRelatedAlloysandisthedirectresponsibilityofSubcommitteeA01.11onSteelPlatesforBoilersandPressureVessels.
CurrenteditionapprovedDec.28,1990.PublishedMay1991.OriginallypublishedasA435–59T.LastpreviouseditionA435/A435M–82(1987).2
ForASMEBoilerandPressureVesselCodeapplications,seerelatedSpeci -cationsSA-435/SA-435MinSectionIIofthatCode.3
AvailablefromAmericanSocietyforNondestructiveTesting,1711ArlingatePlaza,Columbus,OH43228.
1
Copyright©ASTM,100BarrHarborDrive,WestConshohocken,PA19428-2959,UnitedStates.
1
ASTM A252-90 (中文版)_机械/仪表_工程科技_专业资料。ASTM A252-90 (... ASTM标准目录_中文版 268页 2下载券 ASTM A435-A435M-90 2页 1下载券 ...
9页 免费 ASTM A435-A435M-90 2页 2财富值搜你所想,读你所爱 拒绝盗版,营造绿色文库 如要投诉违规内容,请到百度文库投诉中心;如要提出功能问题或意见建议...
ASTM A435-A435M-90 2页 1下载券 ASTM D 2页 2下载券 ASTM--C585-1990 9页 1下载券 ASTM D 822 5页 1下载券喜欢此文档的还喜欢...
(质量)的试验方法 ASTM A434-06 热轧与冷精轧经淬火及回火的合金钢棒规格 ASTM A435/A435M-90(2007) 中厚钢板直射束超声检测规格 ASTM A437/A437M-06 高温...
美国材料与试验协会标准 压力容器用锰硅碳素钢板 ASTM A299/A299M-90 1 范围... S8 符合 A435/A435M 标准要求的超声波检验; S9.磁粉检验; S11.符合 A...
ASTM-A 钢材标准(2)(A314-A496) 标准号 中文名称 英文名称 Standard ...A435/A435M-90(2001) 验 Examination of Steel Plates Standard Specification ...
ASTM标准材质对照_化学_自然科学_专业资料。ASTM 钢管标准对照 A323-93(2000...镇江 1 N+ a# y 2 \: _ A435/A435M-90(2001) 钢板的直射束纵向超声波...
2 引用标准 2.1 ASTM 标准 A20/A2OM 压力容器用钢板的通用要求。 A435/A435M 钢板直射法超声波检测法。 A577/A577M 钢板斜射法超声波检测法。 A578/A578M ...
美国材料与试验协会标准 压力容器用锰硅碳素钢板 ASTM A299/A299M-90 1 范围 ... S8 符合 A435/A435M 标准要求的超声波检验; S9.磁粉检验; S11.符合 A...
(2000) A435/A435M90(2001) A436-84(2001) 适合高温受压部件用经特殊热处理... ASTM-美国涂层标准 28页 1下载券 ASTM美国标准目录 839页 2下载券 美国A...
热门文档