InternationalJournalofHeatandMassTransfer46(2003)

4381–4391
doc.guandang.net
Dendriticheatconvectiononadisc
W.Wechsatola,S.Lorenteb,A.Bejan
ab
a,*
DepartmentofMechanicalEngineeringandMaterialsScience,DukeUniversity,Box90300,Durham,NC27708-0300,USADepartmentofCivilEngineering,NationalInstituteofAppliedSciences(INSA),135AvenuedeRangueil,Toulouse31077,France
Received23December2002;receivedinrevisedform10June2003
Abstract
Inthispaperwedeveloptheoptimaltree-shaped owpathsforcoolingadisc-shapedbodybyconvection.Heatisgenerateduniformlyoverthediscarea.Thecoolantentersthroughthecenterofthedisc,andexitsthroughportspositionedequidistantlyalongtheperimeter.Theunknownisthe owarchitecture.Theconstraintsarethediscsizeandthetotalvolumeoccupiedbytheducts.Itisassumedthattheductsarenarrowenoughsothatthe owishydro-dynamicallyandthermallyfullydeveloped.Theultimategoalistodetermine owarchitecturesthatreachsimulta-neouslytwoobjectives:(i)minimalglobal uid owresistance(orpumpingpower),and(ii)minimalglobalthermalresistance.Whenthearchitectureisoptimizedfor(i),theresultisadendriticstructureinwhicheverygeometricfeatureisuniquelydetermined.Thecorrespondingthermalresistancedecreasesasthetotalmass owrateandthepumpingpowerincrease.Whentheobjectiveis(ii),theoptimalarchitecturehasradialducts,notdendrites.Thecorresponding uid- owresistanceincreasesasthe owrateincreasesandtheglobalthermalresistancedecreases.Puttogether,thesegeometricresultsshowthatmethods(i)and(ii)leadtonearlythesamecombinedperformance(thermaland uid).Examinedmoreclosely,thedendritesproducedbymethod(i)performprogressivelybetterasthelengthscalesbecomesmaller.Optimizedincreasingcomplexityistheroutetohighthermaland uid- owperformanceinthelimitofdecreasingscales.
Ó2003ElsevierLtd.Allrightsreserved.
Keywords:Constructaltheory;Dendritic;Treenetworks;Fractal;Optimization;Smallscales;Topology;Constructaldesign;Miniaturization
1.Objective
Constructaltheory[1]recommendstheuseofahi-erarchicaltree-shaped(dendritic)pathasthegeometricformthatmaximizestheaccessofastreambetweenonepoint(source,orsink)andanin nityofpoints(volume,orarea).Dendritic owarchitectureswere rstreportedforthecoolingofelectronics[2],wheretheywereusedforoptimizingtheinsertionofhigh-conductivitybladesandneedlesintotheheat-generatingpackages.Treesforheatconductionandconvection, nassemblies, uid ow,tra c,economicsandbusinesswereoptimized
Correspondingauthor.Tel.:+1-919-660-5309;fax:+1-919-660-8963.
E-mailaddress:dalford@duke.edu(A.Bejan).
*
basedonconstructaltheory,andarereviewedin[1].Inparticular,treesforconvectionwereanalyzedbyBejanandErrera[3],Bejanetal.[4],Pence[5],Wechsatoletal.[6–8],ChenandCheng[9]andLorenteetal.[10].Treesforconduction(high-conductivityinserts)onadiscwereoptimizedbasedonconstructaltheorybyRochaetal.[11],andbasedonnumericalevolutionaryalgorithmsbyXiaetal.[12].Theinterestinconstructal owarchi-tecturesisspreadingtoothersectorsofthe eldofheatandmasstransfer,asillustratedbyrecentpapersonthehierarchicalgeometricstructuresofboiling[1,13,14](anideacontinuedin[15])andheatexchangersandmassexchangers[16–18].Importantapplicationsarealsofoundincivilengineeringandurbandesign[19].
Inthispaperweconsiderthefundamentalsofopti-mizinggeometrywhentheobjectiveisthecoolingbyconvectionofadisc-shapedbodythatgeneratesheat
0017-9310/$-seefrontmatterÓ2003ElsevierLtd.Allrightsreserved.


doi:10.1016/S0017-9310(03)00295-3