文档下载 文档下载导航
设为首页 | 加入收藏
搜索 请输入内容:  
 导航当前位置: 文档下载 > 所有分类 > 自然科学 > 化学 > Polycarboxylate Fluorescent Indicators as Ion Concentration Probes in Biological Systems
侵权投诉

Polycarboxylate Fluorescent Indicators as Ion Concentration Probes in Biological Systems

Current Medicinal Chemistry 2002, 9, 275-306275

Polycarboxylate Fluorescent Indicators as Ion Concentration Probes inBiological Systems

H.E. Katerinopoulos* and E. Foukaraki

Organic Chemistry Laboratory, Department of Chemistry, University of Crete, Heraklion,Crete, 71 409 Greece

Abstract: A large number of techniques have been applied to monitor the function of freemetal ions in biological systems. Fluorescent ion probes have evolved into an extremelyuseful tool for contemporary experimentalists. Polycarboxylate indicators are widelyused in the determination of metal ion concentrations, especially due to their cellmembrane permeability. The design of these probes required detailed knowledge inrelated fields of medicine, biology, and chemistry, and their preparation demanded theexpertise of organic synthesis. In this review, the basic rationale for the selection ofparticular chemical structures are analyzed, synthetic pathways leading to the desired

structures are presented, often via a retrosynthetic approach, and properties and relative advantages of the use ofthese probes are described. References to specific applications are limited, given the large number of reviews onrelated subjects. Topics such as those related to dextran conjugates that are broad enough to be the subject of adifferent review are not included, and leakage resistance and near-membrane probes are mentioned briefly inseparate sections, although these are chemically similar to typical polycarboxylate dyes. While reference totopics mentioned in related reviews is unavoidable, presentation of material in this review is from the point ofview of a medicinal chemist rather than that of the many experts using these pioneering techniques.

2. INTRODUCTION

The interpretation of phenomena that take place at thecellular level is of vast importance for the understanding ofthe etiology of a plethora of diseases. At the dawn of thetwenty first century medicinal research, in an impressiveoverlap with chemistry and biology, is employing a numberof tools provided by the latter sciences. Synthetic probes thatundergo distinct changes upon binding ions with highselectivity, have enabled researchers to investigate changes inthe intracellular ion concentration levels [1-3].

Fluorescence has been long viewed as a powerful tool forthe selective study of single components in a complexbiological system [4-6]. There is lately a rapidly growinginterest in the development of fluorescent probes with highselectivity for their cellular-component-targets. In general thedesired properties of such probes include a) a large extinctioncoefficient, meaning a high absorbance, b) a significantfluorescence Stokes shift to avoid the overlap of excitationand emission peaks, c) a large fluorescence quantum yield, d)an excitation and/or emission wavelength shift uponcoordination of the probe with its target, such a shift isnecessary for the use of ratio fluorescence which is used todayfor ion concentration calculations, e) an excitationwavelength above 500 nm to minimize "background"fluorescence, which causes signal distortion due to

background fluorescence of cellular components, tissues andbiological fluids (very often, the excitation maximum neededis at the 488 nm line of the argon laser used in techniquessuch as flow cytometry and laser-scanning microscopy), f)high selectivity for the cellular component being studied,which is also translated into a binding constant adjusted tothe mid-point of the physiological concentration range of thecomponent, g) non-toxicity, and h) in the case ofmeasurements of intracellular components, increasedpermeability to the cell membrane.

Ion concentration indicators have some distinctadvantages over other types of biological componentmeasurements. They are intended to function in ahomogeneous aqueous environment. Ion binding has usuallya distinct spectroscopic effect on the probe. Moreover the ionselectivity problem can be solved with modifications ofelectron affinity or steric properties of the coordination siteson the probe [7]. This final task is a challenge for thesynthetic organic chemist who, as part of an interdisciplinaryresearch team, is called to master the synthesis ofcompounds complying with the above requirements.The polycarboxylate fluorescent ion probe method wasfirst envisioned by R. Y. Tsien who, in an euretic as well aselegant approach to the problem, introduced a number ofintracellular calcium probes [8]. The unique efficiency ofthese tools was based on two features in the designedmolecules: the ion chelating moiety, necessary for therecognition of the target, and the fluorophore, usually anextensively conjugated system, sensitive to changes in theelectronic effects resulting upon binding of the probe with thetarget ion. These two chemical moieties have been the

© 2002 Bentham Science Publishers Ltd.

*Address correspondence to this author at the Organic ChemistryLaboratory, Department of Chemistry, University of Crete, Heraklion,Crete, 71 409 Greece; Tel.: +81-238468; Fax: +81-210951; E-mails:secrchem@chemistry.uch.gr & vaschem@chemistry.uch.gr

0929-8673/02 $35.00+.00

Polycarboxylate Fluorescent Indicators as Ion Concentration Probes in Biological Systems