SGLS202A OCTOBER 2003– REVISED OCTOBER 2006

TLE2027 Q1, TLE2037 Q1, TLE2027A Q1, TLE2037A Q1 EXCALIBUR LOW NOISE HIGH SPEED PRECISION OPERATIONAL AMPLIFIERS typical values Typical values presented in this data sheet represent the median (50% point) of device parametric performance.

initial estimates of parameter distributions In the ongoing program of improving data sheets and supplying more information to our customers, Texas Instruments has added an estimate of not only the typical values, but also the spread around these values. These are in the form of distribution bars that show the 95% (upper) points and the 5% (lower) points from the characterization of the initial wafer lots of this new device type (see Figure 5). The distribution bars are shown at the points where data was actually collected. The 95% and 5% points are used instead of±3 sigma, since some of the distributions are not true Gaussian distributions. The number of units tested and the number of different wafer lots used are on all of the graphs where distribution bars are shown. As noted in Figure 5, there were a total of 835 units from two wafer lots. In this case, there is a good estimate for the within-lot variability and a possibly poor estimate of the lot-to-lot variability. This is always the case on newly released products, since there can only be data available from a few wafer lots. The distribution bars are not intended to replace the minimum and maximum limits in the electrical tables. Each distribution bar represents 90% of the total units tested at a specific temperature. While 10% of the units tested fell outside any given distribution bar, this should not be interpreted to mean that the same individual devices fell outside every distribution bar. SUPPLY CURRENT vs FREE-AIR TEMPERATURE 5

I CC Supply Current mA

4.5

4

3.5

3

2.5 75 50 25

8

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ VCC±=±15 V VO= 0 No Load Sample Size= 835 Units From 2 Water Lots 0 25 50 75 100 125 150 TA Free-Air Temperature °C POST OFFICE BOX 655303

95% point on the distribution bar (5% of the devices fell above this point.) 90% of the devices were within the upper and lower points on the distribution bar. 5% point on the distribution bar (5% of the devices fell below this point.)

Figure 5. Sample Graph With Di